2013
DOI: 10.1016/j.chroma.2013.04.049
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive analysis of aminoglycoside antibiotics via hyphenation of transient moving substitution boundary with field-enhanced sample injection in capillary electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(15 citation statements)
references
References 51 publications
0
15
0
Order By: Relevance
“…The most used conventional methods for the detection of antibiotics are instrumental [5], such as capillary electrophoresis [6,7], gas chromatography [8,9] and liquid chromatography [9,10] coupled with mass spectrometry [11]. However, these methods are expensive and present limitations, such as the need for expensive laboratory instruments, time consuming separation/clean-up methodologies, long analysis time, extensive sample handling with multiple washing steps, use of expensive and polluting solvents and the impossibility to perform field analyses, making necessary the development of new sensors to overcome these limitations [12].…”
Section: Introductionmentioning
confidence: 99%
“…The most used conventional methods for the detection of antibiotics are instrumental [5], such as capillary electrophoresis [6,7], gas chromatography [8,9] and liquid chromatography [9,10] coupled with mass spectrometry [11]. However, these methods are expensive and present limitations, such as the need for expensive laboratory instruments, time consuming separation/clean-up methodologies, long analysis time, extensive sample handling with multiple washing steps, use of expensive and polluting solvents and the impossibility to perform field analyses, making necessary the development of new sensors to overcome these limitations [12].…”
Section: Introductionmentioning
confidence: 99%
“…Instead of MSS or AFMC, Shuli et al described a transient moving substitution boundary method that has many parallels to these two approaches and thus has been included here. Their stacking system used crown ethers (18‐crown‐6‐tetracarboxylic acid (18C6H4)) as a pseudostationary phase to transport, release, and accumulate analytes at a substitution boundary.…”
Section: Stackingmentioning
confidence: 99%
“…Schematic illustration of the on‐line concentration with the FESI‐moving substitution boundary method: (A) starting situation of FESI with PSP plug and sample plug injected electrokinetically, (B) sample zone gets stacked under the electrical field, (C) focusing by moving substitution boundary principles, (D) CZE separation of the focused anlaytes. Reproduced from with permission.…”
Section: Stackingmentioning
confidence: 99%
“…Ge et al. reported a method combining FASI with 18‐crown‐6‐tetracarboxylic acid as a pseudostationary phase for the analysis of aminoglycoside antibiotics. Into a capillary filled with the BGE (15 mM Na 2 B 4 O 7 and 55 mM NaOH pH 12.5–12.9, in 0–30% ACN), a short pulse of the pseudostationary phase matrix (150 mM in the BGE) and then a long pulse of the sample (prepared with the pseudostationary phase at lower conductivity and pH 4.0) were introduced.…”
Section: Combined Stacking Techniquesmentioning
confidence: 99%