2009
DOI: 10.1016/j.desal.2008.06.002
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive cadmium potentiometric sensor based on 4-hydroxy salophen as a fast tool for water samples analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(4 citation statements)
references
References 41 publications
0
4
0
Order By: Relevance
“…Around 50% of electrochemical sensor display a detection limit for cadmium below 1 μg/L [ 34 41 ] on modified carbon electrodes. Other micro-sensors give detection limits ranging from 1 μg/L [ 42 46 ] to 100–120 μg/L [ 60 ] and 500 μg/L [ 62 ] on enzymatic biosensors, 3.6 μg/L using anodic stripping voltammetry on screen printed electrodes doped with bismuth nanoparticles [ 54 ] and 20 μg/L by differential pulse voltammetry through polyvinylchloride-2-nitrophenylethyl ether gel [ 58 ].…”
Section: Scientific Articlesmentioning
confidence: 99%
“…Around 50% of electrochemical sensor display a detection limit for cadmium below 1 μg/L [ 34 41 ] on modified carbon electrodes. Other micro-sensors give detection limits ranging from 1 μg/L [ 42 46 ] to 100–120 μg/L [ 60 ] and 500 μg/L [ 62 ] on enzymatic biosensors, 3.6 μg/L using anodic stripping voltammetry on screen printed electrodes doped with bismuth nanoparticles [ 54 ] and 20 μg/L by differential pulse voltammetry through polyvinylchloride-2-nitrophenylethyl ether gel [ 58 ].…”
Section: Scientific Articlesmentioning
confidence: 99%
“…It can be seen that the electrode potential remain almost constant in the pH range of 4-9. The change in potential at higher pH values may be due to the formation of hydroxy complexes of Cd(II) [17]. At lower pH values, a sharp decrease in the electrode response is observed; this result is due to the protonation of carboxylic groups on the TOMAS molecule.…”
Section: Effect Of Ph On Electrodes Responsementioning
confidence: 85%
“…1.0 × 10 − 6 -1.0 × 10 −1 29.1 ± 1 3.5-7.9 13 35 (Rezaei et al 2008b) 4 N,N′-(4 methyl 1,2 phenylene) diquinoline-2 carboxamide 1.0 × 10 −6 -1.0 × 10 −1 29.9 ± 0.5 4-9 8 3-8 (Ensafi et al 2009) 5 4-Hydroxy salophen 1.0 × 10 −6 -1.0 × 10 −1 30.1 ± 1 2.8-8.1 8 20 (Mohan et al 2016) 6 2-Acetylthiophene Semicarbazone 1.0 × 10 −5 -1.0 × 10 −1 29.4 ± 0. .5 × 10 − 7 -1.0 × 10 −1 4.0 × 10 − 7 -2.0 × 10 −1…”
Section: Evaluation Of the Selectivitymentioning
confidence: 99%