2016
DOI: 10.1016/j.jchromb.2016.04.054
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive determination of neurotransmitters in urine by microchip electrophoresis with multiple-concentration approaches combining field-amplified and reversed-field stacking

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 29 publications
0
8
0
Order By: Relevance
“…Zhang et al. presented a method for the determination of neurotransmitters in urine by microchip electrophoresis with multiple‐concentration approaches combining field‐amplified and reversed‐field stacking with LIF detection. Using 90 mM sodium borate at pH 9.4 as the BGE, separation of three neurotransmitters (dopamine, norepinephrine and serotonin) was achieved with LODs of 1.69, 2.35, and 2.73 nM, respectively.…”
Section: Concentration Adjustment (Kohlrausch Stacking)mentioning
confidence: 99%
“…Zhang et al. presented a method for the determination of neurotransmitters in urine by microchip electrophoresis with multiple‐concentration approaches combining field‐amplified and reversed‐field stacking with LIF detection. Using 90 mM sodium borate at pH 9.4 as the BGE, separation of three neurotransmitters (dopamine, norepinephrine and serotonin) was achieved with LODs of 1.69, 2.35, and 2.73 nM, respectively.…”
Section: Concentration Adjustment (Kohlrausch Stacking)mentioning
confidence: 99%
“…An example of this type of analysis is given by Vlčková and Schwarz who developed an ME-based method for simultaneous determination of catecholamines (DA, adrenaline, and noradrenaline (NE)) and their O-methoxylated metabolites (methoxytyramine, normetanephrine, and metanephrine) in mouse brain homogenates [129]. A simple and rapid method employing an on-line multiple-preconcentration approach combining field-amplified stacking and reversed-field stacking for the simultaneous analysis of 5-HT, NE, and DA neurotransmitters in urine samples by ME-LIF was developed by Zhang et al [130]. Their optimized system allowed a very quick (3 min) neurotransmitters separation characterized by nanomolar-level LODs (1.69 for 5-HT, 2.35 for NE, and 2.73 for DA).…”
Section: Me For Separation and Quantification Of Neurotransmitters Inmentioning
confidence: 99%
“…Recently, microchip electrophoresis (MCE), conserving the advantages of low sample consumption and high analysis speed, is increasingly being viewed as a successful alternative to CE technology for rapid analysis. Therefore, an on-line preconcentration strategy combining FASS and reversed-field stacking (RFS) was developed for the efficient and sensitive analysis of DA, NA and 5-HT in real urine samples by MCE with laser-induced fluorescence (LIF) detection [99]. The proposed multiple-preconcentration strategy greatly improved the sensitivity enhancement and surpassed other conventional analytical methods for the quantification of neurotransmitters and can yield a 182- to 292-fold increase in detection sensitivity (Figure 11).…”
Section: Analytical Strategies Of Ba Determinations Based On Separmentioning
confidence: 99%
“…Peak identification: 1, the excess of Cy5; 2, 5-HT; 3, DA; and 4, NE. Figure adopted from reference [99] with the copyright permission.…”
Section: Figurementioning
confidence: 99%