2021
DOI: 10.1016/j.buildenv.2021.108019
|View full text |Cite
|
Sign up to set email alerts
|

Sensitivity analysis of transient heat and moisture transfer in a bio-based date palm concrete wall

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…Nevertheless, the lack of knowledge regarding the intrinsic characteristics of porous materials, coupled with the large number of input parameters that are often challenging to measure, either analytically or experimentally, poses a significant obstacle to the implementation of such models. This challenge has led some researchers to conduct a parametric sensitivity study of the hygrothermal models to investigate the influence of parameters on heat and mass transfer [33][34][35][36]. At the material scale, Benkhaled et al [33] conducted a sensitivity analysis to identify the most influential parameters affecting hygrothermal transfer in hemp concrete.…”
Section: Coupled Heat and Moisture Transfer: A Literature Reviewmentioning
confidence: 99%
“…Nevertheless, the lack of knowledge regarding the intrinsic characteristics of porous materials, coupled with the large number of input parameters that are often challenging to measure, either analytically or experimentally, poses a significant obstacle to the implementation of such models. This challenge has led some researchers to conduct a parametric sensitivity study of the hygrothermal models to investigate the influence of parameters on heat and mass transfer [33][34][35][36]. At the material scale, Benkhaled et al [33] conducted a sensitivity analysis to identify the most influential parameters affecting hygrothermal transfer in hemp concrete.…”
Section: Coupled Heat and Moisture Transfer: A Literature Reviewmentioning
confidence: 99%
“…Moisture content [15,23,24,26,[48][49][50][51][52][53][54][55][56][57][58] Relative humidity [25,[59][60][61][62][63][64][65][66][67][68][69][70][71][72][73] Capillary pressure [74][75][76][77][78][79][80] Vapor pressure [81][82][83][84][85]…”
Section: Driving Potential Referencesmentioning
confidence: 99%
“…This software is used to model the hygrothermal behavior of multilayered building elements exposed to the natural climate. This model has been used by several researchers [59][60][61][62][63][64], with generally satisfactory results.…”
Section: Models Using Relative Humidity As Driving Potentialmentioning
confidence: 99%