2015
DOI: 10.1002/mrm.25850
|View full text |Cite
|
Sign up to set email alerts
|

Sensitivity Enhancement of an Inductively Coupled Local Detector Using a HEMT‐Based Current Amplifier

Abstract: Purpose To improve the signal transmission efficiency and sensitivity of a local detection coil that is weakly inductively coupled to a larger receive coil. Methods The resonant detection coil is connected in parallel with the gate of a HEMT transistor without impedance matching. When the drain of the transistor is capacitively shunted to ground, current amplification occurs in the resonator by feedback that transforms a capacitive impedance on the transistor’s source to a negative resistance on its gate. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…For our example the value ܸ = 10 ି V has been adopted. Other quantities: ݂ = 4.45 ‫ݖܪܯ‬ ܳ = 250 is quality factor of the unloaded coil ܺ = ߱ ‫ܮ‬ = 75 Ω is reactance of the coil ܴ ௨௧ is output resistance of the tuning and matching circuit, corresponding to ܴ ܴ = ఠ బ ொ is resistance of the unloaded coil Values of the capacitances ‫ܥ‬ ଵ and ‫ܥ‬ ଶ are given by (10) and (11): Auxiliary voltage ܸ ଷ is given by (12):…”
Section: Resultsmentioning
confidence: 99%
“…For our example the value ܸ = 10 ି V has been adopted. Other quantities: ݂ = 4.45 ‫ݖܪܯ‬ ܳ = 250 is quality factor of the unloaded coil ܺ = ߱ ‫ܮ‬ = 75 Ω is reactance of the coil ܴ ௨௧ is output resistance of the tuning and matching circuit, corresponding to ܴ ܴ = ఠ బ ொ is resistance of the unloaded coil Values of the capacitances ‫ܥ‬ ଵ and ‫ܥ‬ ଶ are given by (10) and (11): Auxiliary voltage ܸ ଷ is given by (12):…”
Section: Resultsmentioning
confidence: 99%
“…Significant part of the NMR equipment are the RF coils. Many authors studied arrangements of coils to improve the resulting sensitivity [7], [8]. Authors [9]- [11] present different experiments based on the NMR technique.…”
Section: Introductionmentioning
confidence: 99%
“…A quality coil system can solve many problems [6], [7]. If using a commercial NMR scanner, the RF coils are the only facility which can be changed [8], [9]. Experiments may be based on presentation of a new technique which solves problems independently of the scanner or it can be part of it [10]- [13].…”
Section: Introductionmentioning