2021
DOI: 10.1007/s12596-021-00694-y
|View full text |Cite
|
Sign up to set email alerts
|

Sensitivity enhancement of surface plasmon resonance sensor using Al–Au–BaTiO3–Graphene layers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 40 publications
0
4
0
Order By: Relevance
“…One of the sensing methods which fulfills the above-mentioned requirements is optical measurement that utilizes the refractive index characteristic of samples with different concentrations. It has been reported by many studies that the concentration of glucose in the urine biosample ranges from 0 to 15 mg dl −1 (for normal body), 0.625 gm dl −1 , 1.25 gm/dL, 2.5 gm/dL, 5 gm/dL, and 10 gm dl −1 (for diabetic body), with refractive indices of 1.335, 1.336, 1.337, 1.338, 1.341, and 1.347, respectively [6].…”
Section: Introductionmentioning
confidence: 99%
“…One of the sensing methods which fulfills the above-mentioned requirements is optical measurement that utilizes the refractive index characteristic of samples with different concentrations. It has been reported by many studies that the concentration of glucose in the urine biosample ranges from 0 to 15 mg dl −1 (for normal body), 0.625 gm dl −1 , 1.25 gm/dL, 2.5 gm/dL, 5 gm/dL, and 10 gm dl −1 (for diabetic body), with refractive indices of 1.335, 1.336, 1.337, 1.338, 1.341, and 1.347, respectively [6].…”
Section: Introductionmentioning
confidence: 99%
“…Plasmonic materials, such as nickel, silver, aluminum, gold, copper, are employed in sensor design because they exhibit negative real permittivity. [17][18][19][20] There have been several efforts made to improve the sensor's performance. Sensitivity of 70 (RIU À1 ) for an SPR-based grating-coupled sensor [21] and 103 (RIU À1 ) for highly sensitive grating-linked sensor have been proposed.…”
Section: Introductionmentioning
confidence: 99%
“…Two potential routes from which these germs might spread are contaminated food and water. [ 17 ] Therefore, its identification by a theoretical investigation is carried out here. One of the four layers is titanium dioxide (TiO 2 ) of the SPR sensor architecture we used.…”
Section: Introductionmentioning
confidence: 99%
“…Sharmila et al reported that the sensitivity and stability of the SPR sensor can be enhanced using a silicon nano-dielectric layer [19]. Suresh et al achieved the sensitivity enhancement of the SPR-based sensor using the BaTiO 3 dielectric layer with the Al-Au bimetallic layer [20]. Ahmed et al proposed a high-performing SPR-based biosensor using the dielectric layer of Fe 2 O 3 with an Au layer [21].…”
Section: Introductionmentioning
confidence: 99%