2012
DOI: 10.1109/jsen.2012.2183867
|View full text |Cite
|
Sign up to set email alerts
|

Sensors for Corrosion Detection: Measurement of Copper Ions in 3.5% Sodium Chloride Using Screen-Printed Platinum Electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
8
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 33 publications
0
8
0
Order By: Relevance
“…For comparison, solutions containing just Cu are presented in the same figure. Previous studies have characterized copper redox reactions on a Pt electrode in the presence of chloride ions [24][25][26][27][28]. The chloride in our study is found in the electrolyte support (KCl 100 mM).…”
Section: Factors That Influence the Signal And Interferencesmentioning
confidence: 99%
“…For comparison, solutions containing just Cu are presented in the same figure. Previous studies have characterized copper redox reactions on a Pt electrode in the presence of chloride ions [24][25][26][27][28]. The chloride in our study is found in the electrolyte support (KCl 100 mM).…”
Section: Factors That Influence the Signal And Interferencesmentioning
confidence: 99%
“…The nil toxicity, 31 the high overpotentials for oxygen and hydrogen evolutions [8], 32 the high chemical and physical stability in addition to the low 33 capacitive current in aqueous solutions [9], make BDD an attractive 34 electrode material widely used in electroanalysis. One of the most 35 extensively investigated BDD characteristics is the surface 36 property and its influence on the electron transfer process.…”
mentioning
confidence: 99%
“…As DPV is known to be more sensitive than CV by removing non-455 faradic background currents from the current response 456 [18,33,34,60], the determination of copper ions has been carried The interference from ferric ions on copper detection was observed 477 when ferric ion was added into the solution, as shown in Fig. 10.…”
mentioning
confidence: 99%
“…In this figure, an oxidation occurs at 1.158 V / ESM in the presence of Cd 2+ and an oxidation peak in the presence of Cu 2+ at -0.319 V / ESM. These peaks correspond to the oxidation of metallic cadnium and the oxidation of Cu + to Cu 2+ [31,32]. These voltammograms were measured by applying the various optimized values contained in Table 1.…”
Section: Selectivity and Interference Phenomenonmentioning
confidence: 99%