2007
DOI: 10.1016/j.amjsurg.2007.07.008
|View full text |Cite
|
Sign up to set email alerts
|

Sentinel node staging for breast cancer: intraoperative molecular pathology overcomes conventional histologic sampling errors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

9
63
0
5

Year Published

2008
2008
2011
2011

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 95 publications
(77 citation statements)
references
References 19 publications
9
63
0
5
Order By: Relevance
“…The GeneSearch assay was compared with exhaustive serial frozen sectioning practiced by the European Institute of Oncology in Milan and was found to have an equivalent sensitivity to serial frozen sections taken every 1.5-2 mm [4]. A large, multicenter, prospective evaluation by several U.S. centers and a smaller feasibility study by Jules Bordet Institute, Belgium showed sensitivity of over 87% similar to that found in our study, suggesting the technique is reproducible across centers [3,10].…”
Section: Discussionsupporting
confidence: 77%
See 3 more Smart Citations
“…The GeneSearch assay was compared with exhaustive serial frozen sectioning practiced by the European Institute of Oncology in Milan and was found to have an equivalent sensitivity to serial frozen sections taken every 1.5-2 mm [4]. A large, multicenter, prospective evaluation by several U.S. centers and a smaller feasibility study by Jules Bordet Institute, Belgium showed sensitivity of over 87% similar to that found in our study, suggesting the technique is reproducible across centers [3,10].…”
Section: Discussionsupporting
confidence: 77%
“…Our study was a feasibility study and therefore underpowered to address sensitivity of the assay, although the results are generally consistent with the other larger trials [3]. The GeneSearch assay was compared with exhaustive serial frozen sectioning practiced by the European Institute of Oncology in Milan and was found to have an equivalent sensitivity to serial frozen sections taken every 1.5-2 mm [4].…”
Section: Discussionsupporting
confidence: 65%
See 2 more Smart Citations
“…Real-time RT-PCR assays were performed in a one-step reaction in which the expression of three markers genes -mammaglobin (MG), CK-19 and an internal control (IC; porphobilinogen deaminase, PBGD) -was evaluated. Cycle threshold (Ct) cut-off values were predetermined and validated for each marker by the manufacturer on the basis of 2 prospective multisite U.S. clinical trials [9,10]. Cut-off Ct values were ≤31 for MG and ≤30 for CK-19.…”
Section: Bln Assaymentioning
confidence: 99%