2009
DOI: 10.1016/j.jpba.2008.10.016
|View full text |Cite
|
Sign up to set email alerts
|

Separation and on-line preconcentration by stacking and sweeping of charged analytes in the plant by microemulsion electrokinetic chromatography with nonionic surfactants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
7
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(7 citation statements)
references
References 26 publications
0
7
0
Order By: Relevance
“…The front of the zone was focused but the end of the zone was tailing through the low concentration of the micelles at the BGE/sample matrix interface. , Therefore, the concentration of Brij 35 was increased from 0.05 to 0.1% (v/v), and the records of these experiments are shown in Figures and . Thus, the optimum concentration of micelles in the BGE necessary for desorption of the cells from the inner FS capillary surface and for anionic analysis of the cells during tITP/MEKC was reached. ,,− The narrow peak of the MSSA cells was detected again …”
Section: Resultsmentioning
confidence: 97%
See 2 more Smart Citations
“…The front of the zone was focused but the end of the zone was tailing through the low concentration of the micelles at the BGE/sample matrix interface. , Therefore, the concentration of Brij 35 was increased from 0.05 to 0.1% (v/v), and the records of these experiments are shown in Figures and . Thus, the optimum concentration of micelles in the BGE necessary for desorption of the cells from the inner FS capillary surface and for anionic analysis of the cells during tITP/MEKC was reached. ,,− The narrow peak of the MSSA cells was detected again …”
Section: Resultsmentioning
confidence: 97%
“…44 EtOH increases the affinity of the cells for the micelle phase without affecting stacking. 33,34 Both additives also play a significant role in desorption of the cells from the capillary surface. LOD for the analysis utilizing static adhesion in roughened FS capillary was determined as 1 × 10 6 cells mL −1 for MSSA, which is 2 × 10 3 cells suspended in 2 μL of PSS (Table 1).…”
Section: ■ Results and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…While it provides highefficiency separations, the detection limits are higher due to the small sampling volume. A number of on-line concentration strategies have been developed, for example, field amplified sample stacking [1][2][3], isotachophoresis (ITP) [4,5], dynamic pH junction [6,7], pH-mediated stacking [8][9][10], and sweeping [11][12][13]. Sweeping is an effective and convenient way for doing on-line sample concentration in MEKC.…”
Section: Introductionmentioning
confidence: 99%
“…This is followed by switching the polarity back to the positive mode to carry out the actual separation of stacked analytes. This technique has been widely applied to improve detection sensitivity in MEEKC determination of many drugs of different polarities [3].…”
mentioning
confidence: 99%