2013
DOI: 10.1007/s00216-013-7315-1
|View full text |Cite
|
Sign up to set email alerts
|

Separation of nucleotides by hydrophilic interaction chromatography using the FRULIC-N column

Abstract: A stationary phase composed of silica-bonded cyclofructan 6 (FRULIC-N) was evaluated for the separation of four cyclic nucleotides, six nucleoside monophosphates, four nucleoside diphosphates, and five nucleoside triphosphates via hydrophilic interaction chromatography (HILIC) in both isocratic and gradient conditions. The gradient conditions gave significantly better separations by narrowing peak widths. Sixteen out of nineteen nucleotides were baseline separated on the FRULIC-N column in one run. Unlike othe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
22
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 33 publications
(24 citation statements)
references
References 55 publications
2
22
0
Order By: Relevance
“…Target compounds (Padivitage, Dissanayake, & Armstrong, 2013) were guanosine (G), uridine (U), inosine (I); and mono-diand tri-phosphate of adenosine (AMP, ADP, ATP), cytidine (CMP, CDP, CTP), guanosine (GMP, GDP, GTP), inosine (IMP, IDP, ITP) and uridine (UMP, UDP, UTP), respectively, and have been described in a previous paper (Mateos-Vivas, Rodríguez-Gonzalo, . Stock solutions containing the nucleosides and nucleotides reference standards, at 500 lg mL À1 , were prepared in ultra-high quality (UHQ) water.…”
Section: Chemicals and Reagentsmentioning
confidence: 99%
“…Target compounds (Padivitage, Dissanayake, & Armstrong, 2013) were guanosine (G), uridine (U), inosine (I); and mono-diand tri-phosphate of adenosine (AMP, ADP, ATP), cytidine (CMP, CDP, CTP), guanosine (GMP, GDP, GTP), inosine (IMP, IDP, ITP) and uridine (UMP, UDP, UTP), respectively, and have been described in a previous paper (Mateos-Vivas, Rodríguez-Gonzalo, . Stock solutions containing the nucleosides and nucleotides reference standards, at 500 lg mL À1 , were prepared in ultra-high quality (UHQ) water.…”
Section: Chemicals and Reagentsmentioning
confidence: 99%
“…This technique has generally yielded poor separation and unsatisfactory peak shapes for di-and triphosphorylated analytes, and HILIC columns are not straightforward to optimize. [21][22][23] We describe a sensitive IP LC-MS/MS method for separation and quantification of 8 endogenous nucleotides (ATP, CTP, GTP, UTP, dATP, dCTP, dGTP and dTTP) and 2',2'-difluoro-2'-deoxycytidine triphosphate (dFdCTP), the active metabolite of gemcitabine, in peripheral blood mononuclear cells (PBMC).The method has been validated for sensitive and accurate determination of all analytes and innovative steps in preparation of standards are described. The water (analytical grade) was produced in our laboratory via a Milli-Q (Millipore Corporation, MA, USA) deionized water system.…”
Section: Introductionmentioning
confidence: 98%
“…HILIC has been useful at separating hydrophilic analytes and has been successful for the separation of nucleotides, sugar phosphates and nucleotide sugars [7][8][9]. Recently, separation of nucleotides was achieved with a cyclofructan based column using ammonium acetate buffer in both gradient and isocratic methods [7].…”
Section: Introductionmentioning
confidence: 99%
“…These include reversed-phase ion-pairing (RP-IP), porous graphite carbon (PGC), hydrophilic interaction liquid chromatography (HILIC) and mixed mode chromatography [1,2,[4][5][6][7][8][9][10]. Guanosine diphosphate (GDP) sugars and their metabolites were separated by ion-pairing chromatography utilizing ODS-columns (C-18) and ion-pairing agents such as tributylamine with acetic acid [4].…”
Section: Introductionmentioning
confidence: 99%