1992
DOI: 10.1007/bf02276126
|View full text |Cite
|
Sign up to set email alerts
|

Separation of polychlorodibenzo-p-dioxins and-dibenzofurans on the new polar stationary phase DB DIOXIN

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

1994
1994
2016
2016

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(4 citation statements)
references
References 5 publications
0
4
0
Order By: Relevance
“…Isomer specific elution patterns of these compounds are well established for widely used columns [13,14,15]. A few studies were published regarding the PBDE elution pattern [16].…”
Section: Resultsmentioning
confidence: 99%
“…Isomer specific elution patterns of these compounds are well established for widely used columns [13,14,15]. A few studies were published regarding the PBDE elution pattern [16].…”
Section: Resultsmentioning
confidence: 99%
“…The two indices are defined as and The formulation of the indices implies that the concentration of pure 2,3,7,8-substituted congeners is known. However, because all analyses have used DB-5 columns, concentrations determined for 2,3,4,7,8-PnCDF are subject to interferences from coeluting non-2,3,7,8-substituted congeners (42). Representative samples analyzed using both DB-5 and DB-DIOXIN columns (42) have indices that differ only in the third or fourth decimal place from those obtained using a DB-5 column alone (Supporting Information Table 2).…”
Section: Resultsmentioning
confidence: 99%
“…However, because all analyses have used DB-5 columns, concentrations determined for 2,3,4,7,8-PnCDF are subject to interferences from coeluting non-2,3,7,8-substituted congeners (42). Representative samples analyzed using both DB-5 and DB-DIOXIN columns (42) have indices that differ only in the third or fourth decimal place from those obtained using a DB-5 column alone (Supporting Information Table 2). These small differences indicate that coeluting non-2,3,7,8 congeners provide negligible interference for either the PCA models or the two indices.…”
Section: Resultsmentioning
confidence: 99%
“…The development of capillary columns in HRGC permits the congener‐specific determination of a number of these mixtures. The isomer‐specific elution pattern of PCDDs and PCDFs is well established for such widely used columns as DB‐5/DB‐5ms (methyl–5% phenyl‐polysiloxane), DB‐Dioxin (44% methyl–28% phenyl–20% cyanopropyl‐polysiloxane with 8% polyoxyethylene), Sil 88/SP 2331 (100% cyanopropyl‐polysiloxane) 14–16. Analogous studies have been reported on the chromatographic separation of PCB congeners using different columns such as DB‐517 or SGE HT8 18.…”
Section: Chromatographic Separationmentioning
confidence: 92%