2004
DOI: 10.1016/j.cursur.2003.09.011
|View full text |Cite
|
Sign up to set email alerts
|

Sepramesh vs. Dualmesh for abdominal wall hernia repairs in a rabbit model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
11
0
1

Year Published

2005
2005
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(13 citation statements)
references
References 3 publications
1
11
0
1
Order By: Relevance
“…The defect area after three weeks ranged from 32.1±5.5 to 35.6±3.1 squared centimeters and was similar to other reports that made only the acute full-thickness defect with areas ranging from 35 to 40 squared centimeters 9,10,18,[30][31][32][33][34][35][36][37][38] . The hypothetic advantage of our model was to simulate the surgical findings in the human hernia repair.…”
Section: Discussionsupporting
confidence: 71%
See 1 more Smart Citation
“…The defect area after three weeks ranged from 32.1±5.5 to 35.6±3.1 squared centimeters and was similar to other reports that made only the acute full-thickness defect with areas ranging from 35 to 40 squared centimeters 9,10,18,[30][31][32][33][34][35][36][37][38] . The hypothetic advantage of our model was to simulate the surgical findings in the human hernia repair.…”
Section: Discussionsupporting
confidence: 71%
“…In guinea pigs the size was reported as 3x1 cm 26 and in pigs as 10x10 cm 13 , 12x4 cm 12 or 5 cm of diameter 14 . In rabbits the wall defect was referred to sizes of 2x3 cm 27 , 3x3 cm 11,28 , 9x2 cm 18 , 7x3 cm 29 , 5x7 cm [30][31][32] , 7x5 cm 9,33-37 and 5x8 cm 10 . Only one study 38 made reference to the relationship of 2x3 cm wall resection with the percentage of the defect (60-70%) to the total area of the abdominal wall of the mice.…”
Section: Discussionmentioning
confidence: 99%
“…Another possibility is the precoating of PP with extracellular matrix (ECM) components such as collagen. These meshes are available as Sepramesh (Genzyme, Germany) [28]. Precoating with ECM appeared to reduce the incidence of adhesions but increases the infection rate [6,24,25].…”
Section: Discussionmentioning
confidence: 99%
“…In studies comparing HA/CMC-coated PPM with PTFE coated PPM, we see controversial results. In some studies HA/CMC coated PPM is found to be more effective in preventing adhesion formation [21][22][23] whereas in others the opposite occurs [24,25] . ORC, on the other hand is very seldom used in hernia models to prevent adhesion.…”
Section: Discussionmentioning
confidence: 99%