2010
DOI: 10.1016/j.aca.2009.11.018
|View full text |Cite
|
Sign up to set email alerts
|

Sequential injection analysis for automation of the Winkler methodology, with real-time SIMPLEX optimization and shipboard application

Abstract: A multipurpose analyzer system based on sequential injection analysis (SIA) for the determination of dissolved oxygen (DO) in seawater is presented. Three operation modes were established and successfully applied onboard during a research cruise in the Southern ocean: 1st, in-line execution of the entire Winkler method including precipitation of manganese (II) hydroxide, fixation of DO, precipitate dissolution by confluent acidification, and spectrophotometric quantification of the generated iodine/tri-iodide … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0
3

Year Published

2010
2010
2017
2017

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 35 publications
(30 reference statements)
0
8
0
3
Order By: Relevance
“…Horstkotte et al [42] applied the modified simplex methodology to optimize simultaneously four volumetric variables and two concentrations of one in-line prepared reagent of an SIA system in real time. The simplex optimization allowed approaching an ideal starting parameter set with a minimum of experiments.…”
Section: Some Applications Of Simplex Optimization In Analytical Chemmentioning
confidence: 99%
See 1 more Smart Citation
“…Horstkotte et al [42] applied the modified simplex methodology to optimize simultaneously four volumetric variables and two concentrations of one in-line prepared reagent of an SIA system in real time. The simplex optimization allowed approaching an ideal starting parameter set with a minimum of experiments.…”
Section: Some Applications Of Simplex Optimization In Analytical Chemmentioning
confidence: 99%
“…Volumetric and chemicals variables [42] Eighteen organic and inorganic ions Standard solutions Ion exchange chromatography Parameters describing profile for the isocratic separation in ion chromatography [43] Risperidone, 9-hydroxyrisperidone, monoamine and amino acid neurotransmitters…”
Section: Trends For Simplex Optimization In Analytical Chemistrymentioning
confidence: 99%
“…Maior precisão pode ser obtida, por exemplo, pela utilização de bombas peristálticas, de seringa, de pistão ou solenoides, normalmente em conjunto com válvulas solenoides para direcionar o fluxo das soluções [46,47] ou com válvulas de fluxo em loop no casos de sistemas em fluxo [48][49][50].…”
Section: Tituladores Automáticos Descritos Na Literaturaunclassified
“…As bombas peristálticas, no entanto, possuem precisão menor que as bombas de seringa, principalmente pela medição indireta do volume adicionado (por meio das medidas de vazão e tempo) e pelo desgaste dos tubos utilizados [52]. Em uma bomba de seringa o pistão é controlado por um motor de passos, que oferece alta precisão e pode ser empregado em conjunto com seringas de diversos volumes, e por isso são utilizadas quando volumes muito pequenos de titulante são necessários [48,50]. Uma bomba de pistão pode ser utilizada no lugar de uma bomba de seringa, e apesar de permitir fluxos maiores de solução, não atinge a mesma precisão [53].…”
Section: Tituladores Automáticos Descritos Na Literaturaunclassified
See 1 more Smart Citation