2022
DOI: 10.1021/acs.inorgchem.2c01848
|View full text |Cite
|
Sign up to set email alerts
|

Series of TM-OFs as a Platform for Efficient Catalysis and Multifunctional Luminescence Sensing

Abstract: Three novel porous transition-metal–organic frameworks (TM-OFs), formulated as [Co3(DCPN)2­(μ2-OH2)4­(H2O)4]­(DMF)2 (1), [Cd3(DCPN)2­(μ2-OH2)4­(H2O)4]­(DMF)2 (2), and [CdK­(DCPN)­(DMA)] (3), have been successfully prepared via solvothermal conditions based on a 5-(3′,6′-dicarboxylic phenyl) nicotinic carboxylic acid (H3DCPN) ligand. 1 and 2 both have the same porous 3D network structure with the point symbol of {410·614·84}·{45·6}2 based on trinuclear ({Co3} or {Cd3}) clusters, indicating a one-dimensional por… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 61 publications
0
11
0
Order By: Relevance
“…In addition, the lowest record limit of detection (LOD) of LCUH-105 for sensing NFX was calculated to be 0.375 μM by using the equation 3σ/ k (σ is the standard deviation of ten blank tests for the fluorescence intensity of LCUH-105 , k is the slope of the linear relationship between fluorescence intensity and concentration). Except for extraordinary high selectivity, LCUH-105 also indicated high detection sensitivity for sensing NFX, which is equivalent approximately to the sensing ability of other reported MOFs. It is worth noting that the fluorescence sensor LCUH-105 can realize the naked eye detection of trace NFX in water.…”
Section: Results and Discussionmentioning
confidence: 67%
See 3 more Smart Citations
“…In addition, the lowest record limit of detection (LOD) of LCUH-105 for sensing NFX was calculated to be 0.375 μM by using the equation 3σ/ k (σ is the standard deviation of ten blank tests for the fluorescence intensity of LCUH-105 , k is the slope of the linear relationship between fluorescence intensity and concentration). Except for extraordinary high selectivity, LCUH-105 also indicated high detection sensitivity for sensing NFX, which is equivalent approximately to the sensing ability of other reported MOFs. It is worth noting that the fluorescence sensor LCUH-105 can realize the naked eye detection of trace NFX in water.…”
Section: Results and Discussionmentioning
confidence: 67%
“…Thus, the Pd NPs@ LCUH-104 catalytic activity for NPs followed the order of 3-NP > 2-NP > 4-NP, which can be ascribed to their different electron cloud densities of nitro groups in different NP molecules. Because the distance between −OH and −NO 2 is shorter for 2-NP than that of 4-NP, the inductive effect of 2-NP is stronger than that of 4-NP, so 2-NP shows higher reactivity than 4-NP . In contrast, there exist inductive effect without conjugation effect in the 3-NP molecule, which made it easier to gain electrons.…”
Section: Results and Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…MOFs have also been used for the detection of antibiotic molecules. [121][122][123] With the increase in the population globally, the intake of antibiotics has significantly increased, which has a negative effect on the environment. 124 Also, the side effects associated with antibiotics negatively impact human health and cause several diseases.…”
Section: Turn-on Sensing Of Bio-markers and Biological Moleculesmentioning