2014
DOI: 10.1016/j.jlp.2014.09.011
|View full text |Cite
|
Sign up to set email alerts
|

Shake table study of annular baffles in steel storage tanks as sloshing dependent variable dampers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…To verify the correctness of the present multimodal system under seismic excitation, the present results of free surface wave height are compared with the experiment results reported by Hosseinzadeh et al [37]. A scaled steel container with 0.002 m wall thickness was used in the experiment.…”
Section: Comparison Studymentioning
confidence: 66%
“…To verify the correctness of the present multimodal system under seismic excitation, the present results of free surface wave height are compared with the experiment results reported by Hosseinzadeh et al [37]. A scaled steel container with 0.002 m wall thickness was used in the experiment.…”
Section: Comparison Studymentioning
confidence: 66%
“…In another study, the unidirectional shaking table test was conducted after fabricating a miniature model of a liquid storage tank and the sloshing behavior of the fluid was measured using a high-definition (HD) camera [18]. The sloshing behavior was measured in another study using an HD camera to experimentally evaluate the effect of the sloshing reduction devices used in steel storage tanks, which are commonly used in petrochemical complexes and oil storage facilities [19]. The 3D sloshing surface of the liquid in a water tank was measured in a small-scale shaking table test in another study by applying the image processing technique to the liquid [20].…”
Section: Introductionmentioning
confidence: 99%
“…Much research has been undertaken to investigate the dynamic behaviour of water and petroleum storage tanks that are typically composed of steel material that is different from the steel used to manufacture wine tanks, which in some cases have an open top or a floating roof, and that mostly have a low height to radius (H/R) aspect ratio and are either anchored or are unanchored to their foundation and rest on a concrete ring wall (e.g. see [9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25]). Currently limited research has been reported on damage data associated with wine storage tanks, with the most comparable earthquake damage data available being collected between 1933 and 1995 and reported by Cooper [26] based on an inventory of 424 water and petroleum storage tanks.…”
Section: Introductionmentioning