Shaking table test and numerical analysis of a coal-fired power plant equipped with large mass ratio multiple tuned mass damper (LMTMD)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 38 publications
0
5
0
Order By: Relevance
“…The R RMS of the TMD increases with the increase in mass ratio. According to [6], the mass ratio of the TMD can only reach 0.1%-5% due to installation difficulties and economic costs. These mass ratios are much smaller than the optimal mass ratio, so the limited tuned mass cannot effectively reduce the structural vibrations.…”
Section: Effects Of the Auxiliary Mass Ratiomentioning
confidence: 99%
See 2 more Smart Citations
“…The R RMS of the TMD increases with the increase in mass ratio. According to [6], the mass ratio of the TMD can only reach 0.1%-5% due to installation difficulties and economic costs. These mass ratios are much smaller than the optimal mass ratio, so the limited tuned mass cannot effectively reduce the structural vibrations.…”
Section: Effects Of the Auxiliary Mass Ratiomentioning
confidence: 99%
“…In sum, for the particular structure and ground motion in this study, these dampers are not always effective at controlling the seismic responses of the four-story steel frame. According to previous studies [3,[6][7][8][9][10], the control performance of dampers is influenced by many factors, such as the dynamic characteristics of the primary structure, the frequency characteristics and intensities of the seismic inputs, and the damper parameters. Therefore, the conclusions drawn from Figures 10-12 are specific and not generalizable.…”
Section: Effects Of the Auxiliary Mass Ratiomentioning
confidence: 99%
See 1 more Smart Citation
“…Typically, a floor structure exhibits closely spaced modes, and human-induced excitations span a broad frequency range. In such cases, a MTMD system, composed of several TMDs with different frequencies, is known to yield more effective control than a single TMD [38][39][40]. Wang et al [41] proposed an adaptive-passive variable mass MTMD for a floor slab.…”
Section: Introductionmentioning
confidence: 99%
“…To address this problem, dual tuned mass dampers (DTMD) are used in many civil engineering due to their superb robustness in frequency tuning. [30][31][32] In this paper, a vibration model of a vertical cable-dual tuned mass dampers (C-DTMD) system is established. Several non-dimensional parameters are introduced to describe the vibration characteristics of coupled systems.…”
Section: Introductionmentioning
confidence: 99%