2020
DOI: 10.1016/j.istruc.2019.10.004
|View full text |Cite
|
Sign up to set email alerts
|

Shear characterisation of pultruded superstructural FRP-concrete push-outs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(2 citation statements)
references
References 16 publications
0
2
0
Order By: Relevance
“…Serious attention has been paid to stress–strain analysis, failure modes, and determination of shear moduli of such structures and elements as beams; 64,314,315,317,318 beams and structures reinforced/retrofitted with pultruded elements by means of internal or external reinforcement; 319325 box beams; 326 bridge decks; 31,258,327,328 columns; 286,307 connectors; 329 hybrid structures; 330,331 sheet piles; 118 and studs. 332 Besides, the influence of environmental conditions (such as water or elevated temperatures) on the shear characteristics of structures and joints was studied as well. 38,333,334 It is worth noting that particular attention has also been paid to web-flange junctions.…”
Section: Mechanical Properties Of Pultruded Materialsmentioning
confidence: 99%
“…Serious attention has been paid to stress–strain analysis, failure modes, and determination of shear moduli of such structures and elements as beams; 64,314,315,317,318 beams and structures reinforced/retrofitted with pultruded elements by means of internal or external reinforcement; 319325 box beams; 326 bridge decks; 31,258,327,328 columns; 286,307 connectors; 329 hybrid structures; 330,331 sheet piles; 118 and studs. 332 Besides, the influence of environmental conditions (such as water or elevated temperatures) on the shear characteristics of structures and joints was studied as well. 38,333,334 It is worth noting that particular attention has also been paid to web-flange junctions.…”
Section: Mechanical Properties Of Pultruded Materialsmentioning
confidence: 99%
“…They performed 14 push-out tests with varying parameters, such as bolt strength, bolt diameter and bolt-embedding length. Similarly, Etim et al [ 17 ] developed several push-out tests to investigate the shear transmission between normal concrete and GFRP profiles. However, analytical methods have not yet been fully developed enough to precisely predict the shear capacity of the composite sections due to the complexity of the FRP–concrete connection.…”
Section: Introductionmentioning
confidence: 99%