Shear Wave Velocity Imaging Using Transient Electrode Perturbation: Phantom and ex vivo Validation

Abstract: This paper presents a new shear wave velocity imaging technique to monitor radio-frequency and microwave ablation procedures, coined electrode vibration elastography. A piezoelectric actuator attached to an ablation needle is transiently vibrated to generate shear waves that are tracked at high frame rates. The time-to-peak algorithm is used to reconstruct the shear wave velocity and thereby the shear modulus variations. The feasibility of electrode vibration elastography is demonstrated using finite element m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
48
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(49 citation statements)
references
References 48 publications
1
48
0
Order By: Relevance
“…We noted that small differences in envelope SNR had a large effect on the attenuation estimation variance once the SNR began to significantly deviate from 1.91. Ex vivo porcine (Bush et al, 1993; Zhou et al, 2013), bovine (Bevan and Sherar, 2001a, 2001b; Dewall et al, 2010; Gertner et al, 1997; Luchies et al, 2012, 2012; Parker, 1983; Pereira and Maciel, 2001), rat (Kemmerer and Oelze, 2012), and human (Machado et al, 2006) liver have all been used for the development of ultrasonic tissue characterization algorithms based on features extracted from RF data. However, we are not aware of any studies comparing estimates of envelope statistics in excised liver with estimates of envelope statistics in an in vivo setting.…”
Section: Discussionmentioning
confidence: 99%
“…We noted that small differences in envelope SNR had a large effect on the attenuation estimation variance once the SNR began to significantly deviate from 1.91. Ex vivo porcine (Bush et al, 1993; Zhou et al, 2013), bovine (Bevan and Sherar, 2001a, 2001b; Dewall et al, 2010; Gertner et al, 1997; Luchies et al, 2012, 2012; Parker, 1983; Pereira and Maciel, 2001), rat (Kemmerer and Oelze, 2012), and human (Machado et al, 2006) liver have all been used for the development of ultrasonic tissue characterization algorithms based on features extracted from RF data. However, we are not aware of any studies comparing estimates of envelope statistics in excised liver with estimates of envelope statistics in an in vivo setting.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, the full data set is assembled by vibrating the needle multiple times and recording data in synchronization at five lateral locations using narrow focussed beams. This provides a frame rate of around 2000 Hz [9]. A 128-element linear array transducer operating at 5 MHz center frequency, 4.5 cm imaging depth, 3 cm focal depth and each A-line sampled at 40 MHz is used for RF echo data acquisition.…”
Section: Methodsmentioning
confidence: 99%
“…It has potential to augment traditional B-scans and assist the clinician in delineating ablation boundaries more accurately. Unlike X-ray computed tomography (CT) or magnetic resonance imaging (MRI), traditional ultrasound elastography has been limited to single imaging planes, over which strain is estimated, and the Young's modulus (stiffness) is reconstructed by solving the inverse problem [6], [7], [8], [9]. Shear wave velocity (SWV) and shear modulus can also be estimated for these imaging planes [10].…”
Section: Introductionmentioning
confidence: 99%