Short‐term results of rotoresection for benign prostatic hyperplasia: a prospective study of safety and efficacy

Abstract: of >1.8 mg/mL were excluded. The adenoma was resected using the Rotoresect® system (Karl Storz, Tuttlingen, Germany); the mean ( SD ) operative duration was 45.2 (9.9) min. The catheter was removed after 1.97 (0.3) days and patients assessed at 1, 3 and 6 months after surgery by an AUA score, Q max , blood haemoglobin level, urine analysis and transrectal ultrasonography; all patients but two completed the follow-up. RESULTSAt 6 months the mean ( SD ) AUA score decreased from 20.5 (3.8) to 1.6 (1.3), the Q max… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2005
2005
2012
2012

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 13 publications
0
2
0
1
Order By: Relevance
“…The patients assessed were those reported previously [3]; they were aged 50–80 years, with an AUA‐7 symptom index of ≥ 13, a maximum urinary flow rate (Q max ) of ≤12 mL/s with a voided volume of ≥ 125 mL, a prostatic length determined on cystoscopy of 3–5 cm, a prostate volume of 20–80 mL, and a PSA level of <4 ng/mL, or 4–10 ng/mL with a negative prostate biopsy. All patients gave informed written consent.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The patients assessed were those reported previously [3]; they were aged 50–80 years, with an AUA‐7 symptom index of ≥ 13, a maximum urinary flow rate (Q max ) of ≤12 mL/s with a voided volume of ≥ 125 mL, a prostatic length determined on cystoscopy of 3–5 cm, a prostate volume of 20–80 mL, and a PSA level of <4 ng/mL, or 4–10 ng/mL with a negative prostate biopsy. All patients gave informed written consent.…”
Section: Methodsmentioning
confidence: 99%
“…The Rotoresect TM (Karl Storz, Tuttlingen, Germany) system is a modification of the electrovaporization method, that combines rotation of a specially designed electrode with high‐frequency current, and initial clinical results with this system were promising. The present report evaluated the durability of the previously reported success [3].…”
Section: Introductionmentioning
confidence: 99%
“…Ne ben ei ner ho hen Ener gieleis tung von 180-220 W [15,16,17,24] sind der zeit noch un zu rei chen de kli ni sche Er fah rungen und Lang zei t er geb nis se an zu mer ken. Da rü ber hi naus er for dert das Ver fah ren eine Um stel lung der Re sek ti ons tech nik und so mit einen Lern pro zess für den Opera teur.…”
Section: Wel Che An Sät Ze Konn Ten Sich Durch Set Zen?unclassified