2014 IEEE PES Transmission &Amp; Distribution Conference and Exposition - Latin America (PES T&D-La) 2014
DOI: 10.1109/tdc-la.2014.6955204
|View full text |Cite
|
Sign up to set email alerts
|

Shunt active power filter for harmonic compensation of two-phase nonlinear loads

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 13 publications
0
2
0
1
Order By: Relevance
“…In [27], a novel interpretation of the classic p-q theory is devised by mapping two-phase voltages and currents into the αβ frame by means of linear transformations. Although care must be taken using [28], since the method presents particular interpretations in relation to [29], such approach provides effective reactive power compensation, along with harmonic and unbalance current mitigation, as well as neutral current reduction in 2Φ3w grids. With the work in [22], another power theory, namely Conservative Power Theory (CPT) [36], has been explored for being applied to the control of APFs in 2Φ3w networks, achieving selective compensation.…”
Section: A Comprehensive Literature Reviewmentioning
confidence: 99%
See 1 more Smart Citation
“…In [27], a novel interpretation of the classic p-q theory is devised by mapping two-phase voltages and currents into the αβ frame by means of linear transformations. Although care must be taken using [28], since the method presents particular interpretations in relation to [29], such approach provides effective reactive power compensation, along with harmonic and unbalance current mitigation, as well as neutral current reduction in 2Φ3w grids. With the work in [22], another power theory, namely Conservative Power Theory (CPT) [36], has been explored for being applied to the control of APFs in 2Φ3w networks, achieving selective compensation.…”
Section: A Comprehensive Literature Reviewmentioning
confidence: 99%
“…Other applications of 2Φ3w APFs propose different converter topologies. For instance, a five-level shunt APF configuration using predictive controllers is devised for compensation of current unbalance and harmonics in [29]. The same topology is employed for reactive power compensation in [30], presenting an innovative DC bus capacitor voltage balancing strategy that requires a reduced number of sensors.…”
Section: A Comprehensive Literature Reviewmentioning
confidence: 99%
“…El Filtro activo de potencia (APF) para aplicaciones monofásicas y trifásicas se encuentra ampliamente reportada en la literatura técnica en [1], [2], [3], [4], pero hay una falta de documentos que aborden aplicaciones en sistemas bifásicos. Entre los pocos trabajos sobre sistemas bifásicos están [5], [6], donde los autores han propuesto el uso de dos convertidores de 5 niveles para la compensación de los armónicos de corriente entre dos fases de un sistema trifásico como se muestra en la Fig. 2.…”
Section: Filtros Activos De Potencia En Sistemas Bifásicosunclassified