2021
DOI: 10.1016/j.sab.2021.106266
|View full text |Cite
|
Sign up to set email alerts
|

Silicon determination via a SiO rotational line using high-resolution graphite furnace molecular absorption spectrometry: A straightforward approach for the analysis of solid samples prepared as suspensions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…Application of this correction method improved results for Pb in NIST SRMs 1570a (spinach leaves) from 0.350 AE 0.130 to 0.241 AE 0.068 mg kg −1 (reference value 0.2 mg kg −1 ). Although analyte oxide species are oen the source of interference in CS-ETAAS, they can sometimes be used to advantage as demonstrated in a method 160 for the determination of Si based on molecular absorption by SiO. This was successfully applied to the analysis of solid sample suspensions, including two soil and two sediment CRMs.…”
Section: Reference Materialsmentioning
confidence: 99%
“…Application of this correction method improved results for Pb in NIST SRMs 1570a (spinach leaves) from 0.350 AE 0.130 to 0.241 AE 0.068 mg kg −1 (reference value 0.2 mg kg −1 ). Although analyte oxide species are oen the source of interference in CS-ETAAS, they can sometimes be used to advantage as demonstrated in a method 160 for the determination of Si based on molecular absorption by SiO. This was successfully applied to the analysis of solid sample suspensions, including two soil and two sediment CRMs.…”
Section: Reference Materialsmentioning
confidence: 99%
“…For example, Si can be quickly determined at a percentage level via a direct HR-CS GF MAS procedure if solid samples, difficult to dissolve, are prepared and analyzed as suspension. 20…”
Section: Introductionmentioning
confidence: 99%
“…[1][2][3][4][5][6] Nowadays, for some elements, two approaches are available as apart from the possibility of using AAS, HR-CS MAS methods were developed. [7][8][9][10][11][12][13][14][15][16][17][18][19][20] Phosphorus was determined via PO [7][8][9][10][11][12][13]15,16 or P 2 14 molecules, aluminum via AlF 17 or AlH 18 molecules and silicon via SiO molecules. 19,20 In the determinations, the HR-CS FMAS 7,8,[11][12][13]19 or the HR-CS GFMAS 9,10,[14][15][16][17][18]20 techniques were applied.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations