2012
DOI: 10.1002/jps.23328
|View full text |Cite
|
Sign up to set email alerts
|

Silicone-Oil-Based Subvisible Particles: Their Detection, Interactions, and Regulation in Prefilled Container Closure Systems for Biopharmaceuticals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
52
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 56 publications
(56 citation statements)
references
References 20 publications
3
52
1
Order By: Relevance
“…Considering the surface-active properties of PS-20, the observed increase of silicone-oil droplets generated in PS-20 samples (Figure 3) was consistent with previous reports (Felsovalyi et al, 2012).…”
Section: Agitation In Siliconized Pfs Increases Aggregation Formationsupporting
confidence: 91%
See 1 more Smart Citation
“…Considering the surface-active properties of PS-20, the observed increase of silicone-oil droplets generated in PS-20 samples (Figure 3) was consistent with previous reports (Felsovalyi et al, 2012).…”
Section: Agitation In Siliconized Pfs Increases Aggregation Formationsupporting
confidence: 91%
“…However, the focus has been the larger sub-visible size range of particulates i.e. > 0.5 m (Felsovalyi et al;Krayukhina et al, 2015;Teska et al); due to the current lack of available technologies that are sensitive to the detection of smaller particles, whilst capable of differentiating between proteinaceous and foreign particulates (e.g. silicone-oil).…”
Section: Common Termsmentioning
confidence: 99%
“…Several recent studies have focused on how proteins may be affected by exposure to these interfaces. In particular, protein adsorption to both air–water and silicone oil–water interfaces has been shown to promote protein aggregation and particle formation …”
Section: Introductionmentioning
confidence: 99%
“…In addition, there is a growing concern about the number of particles between 0.1 and 10 μm in protein formulations, as particles in this size range may be the most immunogenic and are considered a critical quality attribute . With new technologies, the ability to quantify and characterize particles in the 0.1–10 μm size range has significantly improved, and as a result, several recent studies have focused on identifying the extent to which these particles arise in protein therapeutic products and their impact on product quality, safety, and immunogenicity . For example, Barnard et al suggest a link between the presence of aggregates and particles in interferon‐β products and the production of neutralizing antibodies in patients.…”
Section: Introductionmentioning
confidence: 99%
“…To this end, lubricity in glass syringes is generally achieved using medical grade silicone oil, typically a polydimethylsiloxane (PDMS, Me 3 Si(OSiMe 2 ) n OSiMe 3 ), n∼ 380, 1000 cSt viscosity). This material provides the correct viscosity and shear-thinning properties [6, 7, 8, 9] while forming an excellent, biocompatible seal for the aqueous solution [10].…”
Section: Introductionmentioning
confidence: 99%