Silk flow-diverter stent for the treatment of complex intracranial aneurysms: A one-year follow-up multicenter study

Abstract: Background Flow-diverter stents have been successfully used in the treatment of complex aneurysms with limited therapeutic alternatives. We report our experience using the Silk flow diverter (SFD; Balt Extrusion, Montmorency, France) for the treatment of complex aneurysms in four Argentine centers. Methods We conducted a retrospective review of 246 consecutive patients who were treated with the SFD at four… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0
2

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 32 publications
(88 reference statements)
0
6
0
2
Order By: Relevance
“…1). 2,6,[14][15][16][17][18][19][20][21][22][23][24][25] All prospective and retrospective observational cohort studies were included.…”
Section: Search Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…1). 2,6,[14][15][16][17][18][19][20][21][22][23][24][25] All prospective and retrospective observational cohort studies were included.…”
Section: Search Resultsmentioning
confidence: 99%
“…After selection, 14 studies were chosen, 2,6,14-25 1 prospective observational cohort study and 13 retrospective observational cohort studies involving 1,021 patients treated for aneurysms. 2,6,[14][15][16][17][18][19][20][22][23][24][25] The mortality rate was 2.84% (95% confidence interval [CI] 0.00-2.75, P=0.83, I 2 =0%) (Table 1).…”
Section: Overview Of Included Studiesmentioning
confidence: 99%
“…The FD may change local hemodynamics rather than simply covering the ostium and may need some time for a complete thrombosis inside the aneurysm and intimal endothelialization of the FD after the flow has been modified. According to the literature, [27][28][29][30] the occlusion rate is variable. Our 6-month occlusion rate was slightly lower, but we found a similar rate at 12 months.…”
Section: Discussionmentioning
confidence: 99%
“…Silk device, achieving a complete occlusion rate of 93.9% with morbidity and mortality rates of 4.2% and 2.1%, respectively, at year follow-up. 41…”
Section: New Devices and Technologiesmentioning