2013
DOI: 10.1007/s10895-013-1191-0
|View full text |Cite
|
Sign up to set email alerts
|

Simple and Sensitive Synchronous- Fluorescence Method for the Determination of Trace Bisphenol S Based on its Inhibitory Effect on the Fluorescence Quenching Reaction of Rhodamine B

Abstract: An inhibitory kinetic fluorimetric method is reported for the determination of trace bisphenol S (BPS). The proposed method is based on the inhibitory effect of BPS on the fluorescence quenching of rhodamine B (RhB) caused by potassium bromate in a dilute phosphoric acid medium. Under the optimal conditions of the experiment, the detection limit for BPS was 0.021 mg/L, and the linear range of determination was from 0.035 mg/L to 0.750 mg/L. The relative standard deviations of 11 measurements for 0.20 mg/L and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
7
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 23 publications
0
7
0
Order By: Relevance
“…AFM height information, 3d rendering, and TEM images ( Fig. 25,26 Further analyses of emission spectra suggested that full width at half maximum (FWHM) of emission peak for CDWF was not significantly different than that peak obtained from CDSD. Fig.…”
Section: Afm and Tem Examinationmentioning
confidence: 93%
“…AFM height information, 3d rendering, and TEM images ( Fig. 25,26 Further analyses of emission spectra suggested that full width at half maximum (FWHM) of emission peak for CDWF was not significantly different than that peak obtained from CDSD. Fig.…”
Section: Afm and Tem Examinationmentioning
confidence: 93%
“…Based on the increased production and use of BPS, it was used as a model organic pollutant, and many analytical procedures were introduced for its sensitive assay. These approaches include UV-spectrophotometry, 11 high-pressure liquid chromatography (HPLC) 12 and ultra performance/pressure liquid chromatography with mass spectrometric detection (UPLC-MS/MS). 13 Aside from their sensitivity, all of the preceding approaches have the disadvantages of expensive instrumentation, long experimental times, and the need for expertise personnel.…”
Section: Introductionmentioning
confidence: 99%
“…Chromatographic technique has played an important role in the analysis of bisphenols in various samples , including LC–UV , LC coupled to fluorescence detector , GC–MS , and LC–MS/MS . Although these methods have acceptable results, their disadvantages commonly exist.…”
Section: Introductionmentioning
confidence: 99%