2003
DOI: 10.1021/bk-2003-0853.ch007
|View full text |Cite
|
Sign up to set email alerts
|

Simple Determination of Herbicides in Rice Paddy Water by Immunoassay

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2004
2004
2019
2019

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…Water samples were mixed with 900 µL of distilled water and stored at −18°C until analysis of the BSM concentrations. The BSM analysis was carried out using a competitive enzyme‐linked immunosorbent assay ( elisa ) (Ishii 2003; Miyake et al . 2003).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Water samples were mixed with 900 µL of distilled water and stored at −18°C until analysis of the BSM concentrations. The BSM analysis was carried out using a competitive enzyme‐linked immunosorbent assay ( elisa ) (Ishii 2003; Miyake et al . 2003).…”
Section: Methodsmentioning
confidence: 99%
“…Water samples were mixed with 900 mL of distilled water and stored at -18∞C until analysis of the BSM concentrations. The BSM analysis was carried out using a competitive enzyme-linked immunosorbent assay (ELISA) (Ishii 2003;Miyake et al 2003). Water samples or BSM standard solutions were mixed with equal volumes of BSM hapten-enzyme conjugated solution, and 100 mL of each mixture was incubated for 1.0 h at 25∞C in microtiter plates with 96 wells coated with anti-BSM monoclonal antibody.…”
Section: Bensulfuron Methyl Analysismentioning
confidence: 99%
“…Solid-phase extraction, supercritical-fluid extraction, liquid-liquid extraction and QuEChERS are generally adopted in paddy sample preparation, and QuEChERS is the most frequently used method [26]. Analytical methods for pyrazosulfuron-ethyl and bensulfuron-methyl have been mainly focused on high performance liquid chromatography (HPLC) [27], capillary electrophoresis (CE) [28], gas chromatography-tandem mass spectrometry (GC-MS) [29], immunoassay [30], and liquid chromatography-tandem mass spectrometry (LC-MS) [31]. Acetochlor and butachlor analysis have been primarily performed on GC [32], HPLC [21], and GC-MS [33].…”
Section: Introductionmentioning
confidence: 99%
“…dc-ELISA. A dc-ELISA for residue analysis of emamectin benzoate was constructed as described previously (23). Rabbit anti-mouse IgG antibody (100 µL, 10 µg/mL) in PBS was added to each well of a 96-well microtiter plate, and the plate was incubated overnight at 4 °C.…”
Section: Introductionmentioning
confidence: 99%