2022
DOI: 10.1016/j.microc.2021.106950
|View full text |Cite
|
Sign up to set email alerts
|

Simple laser-induced graphene fiber electrode fabrication for high-performance heavy-metal sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(14 citation statements)
references
References 36 publications
2
12
0
Order By: Relevance
“…As shown in Figure d, three main characteristic peaks appear in the prepared LIG, i.e., D peak (1348.75 cm –1 ), G peak (11585.15 cm –1 ), and 2D peak (2695.45 cm –1 ) related to structural defects, graphite carbon, and secondary region boundary phonons, respectively . The intensity ratio of 2D peak to G peak of about 0.8 indicates that the prepared LIG consisted of multi-layer graphene . The contact angle of the fabricated LIG was measured as small as 12° (Figure S1).…”
Section: Resultsmentioning
confidence: 96%
See 3 more Smart Citations
“…As shown in Figure d, three main characteristic peaks appear in the prepared LIG, i.e., D peak (1348.75 cm –1 ), G peak (11585.15 cm –1 ), and 2D peak (2695.45 cm –1 ) related to structural defects, graphite carbon, and secondary region boundary phonons, respectively . The intensity ratio of 2D peak to G peak of about 0.8 indicates that the prepared LIG consisted of multi-layer graphene . The contact angle of the fabricated LIG was measured as small as 12° (Figure S1).…”
Section: Resultsmentioning
confidence: 96%
“…This segmented fitting, which is commonly used in the investigation of heavy metal detection, ,, indicates that the sensitivity of the sensor is lower in the range of low-Pb 2+ concentration, i.e., 0.1772 μA·(μg·L –1 ) −1 in 1–5 μg·L –1 and 0.7081 μA·(μg·L –1 ) −1 in 10–100 μg·L –1 . The reason could be attributed to the competition between Pb 2+ and H + .…”
Section: Resultsmentioning
confidence: 97%
See 2 more Smart Citations
“…22,67 The higher sensitivity at a lower concentration range could be explored in further enhancement of sensitivity owing to the possibilities of the porous nature of LIG and its modification by other nanomaterials. 68 The linear regression equations for the two linear ranges can be expressed as I PC (μA) = 0.0615C (μM) + 14.77, with an R 2 value of 0.9917 and I PC (μA) = 2.0779C (mM) + 12.0830, with R 2 = 0.9949. The corresponding limit of detection is 95 nM (S/N = 3).…”
Section: Electrochemical Response Of 4-np On Lig the Cyclic Voltammet...mentioning
confidence: 99%