2022
DOI: 10.1016/j.xpro.2022.101362
|View full text |Cite
|
Sign up to set email alerts
|

Simplified mass cytometry protocol for in-plate staining, barcoding, and cryopreservation of human PBMC samples in clinical trials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 5 publications
0
1
0
Order By: Relevance
“…To the best of our knowledge, this is the first time these differences are reported, mainly because in previous studies, fixed numbers of cells were measured per sample, whereas all the stained sample was analyzed in our study (12,19). The lower cell recovery by MC vs. SFC is likely caused by the longer sample preparation and staining protocols with more centrifugation steps, which lead to the loss of up to 50% of cells (50). In addition, a limited instrument-related cell recovery has also been reported (30% to 50%) for MC (17,50).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…To the best of our knowledge, this is the first time these differences are reported, mainly because in previous studies, fixed numbers of cells were measured per sample, whereas all the stained sample was analyzed in our study (12,19). The lower cell recovery by MC vs. SFC is likely caused by the longer sample preparation and staining protocols with more centrifugation steps, which lead to the loss of up to 50% of cells (50). In addition, a limited instrument-related cell recovery has also been reported (30% to 50%) for MC (17,50).…”
Section: Discussionmentioning
confidence: 99%
“…The lower cell recovery by MC vs. SFC is likely caused by the longer sample preparation and staining protocols with more centrifugation steps, which lead to the loss of up to 50% of cells (50). In addition, a limited instrument-related cell recovery has also been reported (30% to 50%) for MC (17,50).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The data were normalized using the FCS Processing tab of the Fluidigm CyTOF Software 7.0.8493. The detailed protocol is available ( 19 ), and Supplementary Table S1 lists the antibodies used in the panel. The CyTOF data were quantified and analyzed using the CATALYST Pipeline ( 17, 18 ).…”
Section: Methodsmentioning
confidence: 99%