2020
DOI: 10.1111/ajgw.12450
|View full text |Cite
|
Sign up to set email alerts
|

Simplified measures of copper fractions in wine: colorimetric and filtration‐based approaches

Abstract: Background and Aims Simple methods for determining Cu forms in wine do not currently exist. This study demonstrates the relevance of measuring a specific fraction of Cu in wine, and introduces simplified methods for its measurement utilising either colorimetry, or filtration in combination with routine measures of total Cu in wine. Methods and Results Electrochemically detectable Cu provided a threshold level of Cu that related directly to the accumulation of free hydrogen sulfide and free methanethiol in bott… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 27 publications
(70 reference statements)
1
5
0
Order By: Relevance
“…Consistent with past results 15,16 and the known complexation reaction between Cu(II) and H 2 S, once the combined Cu fractions I and II fell below 0.02 mg/L, a link to potential GC-SCD free H 2 S accumulation (i.e., >1.0 μg/L) was evident (Figure 4a). This was also demonstrated for the first time when free H 2 S was measured by GDT (Figure 4b).…”
Section: ■ Materials and Methodssupporting
confidence: 90%
See 2 more Smart Citations
“…Consistent with past results 15,16 and the known complexation reaction between Cu(II) and H 2 S, once the combined Cu fractions I and II fell below 0.02 mg/L, a link to potential GC-SCD free H 2 S accumulation (i.e., >1.0 μg/L) was evident (Figure 4a). This was also demonstrated for the first time when free H 2 S was measured by GDT (Figure 4b).…”
Section: ■ Materials and Methodssupporting
confidence: 90%
“…Total concentrations of Al, Cu, Fe, Mn, Mg, and Zn were determined by ICPOES at Laboratory 2 as described by Kontoudakis et al 14 The colorimetric analysis of white wine for total Cu and Cu fractions was determined at Laboratory 2 as described by Kontoudakis et al 22 and Clark, Zhang, and Kontoudakis. 16 In brief, total Cu concentration was measured after incubating 10 mL of wine with 12 mg/L bichinchonic acid (BCA), 380 mg/L ascorbic acid and 10 mg/L silver(I) for 30 min, while Cu fractions I and II were determined after 0 and 30 min of incubation of wine with 12 mg/L BCA and 380 mg/L ascorbic acid but without silver(I) addition. The concentration of Cu fraction III was calculated as the difference between the total Cu concentration and the combined concentrations of Cu fractions I and II.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the last part of the optimization studies, the influence of the ionic additive percentage on the sensor performance was examined. Therefore, a series of all-solid-state composite electrodes were produced by adding ionic additives in the ratios varying between (w/w) 0.5-2.5 % to the composition of (w/w) 20.0 % paraffin oil, (w/w) 5.0 % MWCNT, and (w/w) 3.0 % ionophore (NaTPB) (Composition [13][14][15][16][17] and their performance characteristics were compared. The data given in Table 2 indicate that none of the studied compositions including ionic additive had any premptory effect on the electrode performances.…”
Section: Optimization Of the Sensor Compositionmentioning
confidence: 99%
“…Considering the toxic effects of copper, its determination is quite critical. There are a number of analytical techniques that have been reported for the determination of copper ions at very low concentration levels, including ion chromatography [7,8], UV-Vis Spectrophotometry [9,10], flame atomic absorption spectrometry (FAAS) [11,12], graphite-furnace atomic absorption spectrometry (GF AAS) [13], Colorimetry [14][15][16], fluorescence spectroscopy [17,18], ICP-MS [19], ICP-OES [20], ICP-AES [21], Capilarry Electrophoresis-UV [22], titrimetry [23], gravimetry [24], electrogravimetry [25] and electrochemical methods [26][27][28][29][30].…”
Section: Introductionmentioning
confidence: 99%