Abstract:ABSTRACT. Radiography inspection have been used in this work to detects and image the corrosion in the outside surface of the pipe. Gamma ray with 0.662 MeV from 127 Cs source have been chosen for this inspection while NaI(Tl) detector is use to detect and collect the scatter photons with radius 6cm. A simulation follow the history of photon by using Fortran Language and concerned on the effect of Compton scattering angle on the count rate of scatter photons and on the quality of the image. The Compton scatte… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.