2019
DOI: 10.3390/en12122321
|View full text |Cite
|
Sign up to set email alerts
|

Simulation-Based Comparison Between the Thermal Behavior of Coaxial and Double U-Tube Borehole Heat Exchangers

Abstract: In this study, the thermal behavior of the coaxial and double U borehole heat exchangers was investigated using numerical simulations in both the long- and short-term. As a reference for borehole heat exchanger specifications, the existing coaxial and double U probes of a geothermal heat pump installed within the Horizon 2020 research project named “Cheap GSHPs” were considered. Nine years of simulations revealed that when borehole heat exchangers are subjected to a balanced thermal load, and intermittent oper… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 28 publications
(23 citation statements)
references
References 14 publications
0
23
0
Order By: Relevance
“…To increase the heat transfer performance of the ground heat exchanger, previous studies have been conducted to change its shape or materials [5][6][7][8][9]. Most of the studies [5][6][7][8][9] on the shape of the ground heat exchanger, compared heat transfer performances through numerical simulation or experimentally analyzed the ground effective thermal conductivity through TRT. However, for the GSHP system applied to actual buildings, a steady state is maintained during a short period of time and the system is mostly operated under part-load condition.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…To increase the heat transfer performance of the ground heat exchanger, previous studies have been conducted to change its shape or materials [5][6][7][8][9]. Most of the studies [5][6][7][8][9] on the shape of the ground heat exchanger, compared heat transfer performances through numerical simulation or experimentally analyzed the ground effective thermal conductivity through TRT. However, for the GSHP system applied to actual buildings, a steady state is maintained during a short period of time and the system is mostly operated under part-load condition.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…The heat pump COP can be expressed as the ratio of the heating capacity to the required power, and the uncertainties of the heating capacity and the heat pump power are independent. Therefore, the uncertainty of the heat pump COP can be expressed as shown in Equation (8). The measurement error of the heat transfer rate and COP calculated using Equations (6)-(8) was ± 4.0%.…”
Section: Performance Calculation Equationmentioning
confidence: 99%
See 3 more Smart Citations