2004
DOI: 10.1016/j.apradiso.2003.12.010
|View full text |Cite
|
Sign up to set email alerts
|

Simulation of a radiotracer experiment by flow and detection-chain modelling: a first step towards better interpretation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 4 publications
0
5
0
Order By: Relevance
“…Furthermore, based on its accessible availability and favorable nuclear properties, 99m Tc received considerable attention in multi-disciplinary fields. Recently, it has been involved in a variety of industrial radiotracer applications (Fauquex et al, 1983;Kantzas et al, 2000;Bandeira et al, 2002;Borroto et al, 2003;Berne and Thereska, 2004;Hughes et al, 2004;Thyn and Zitny, 2004;Dash et al, 2012;Pavlovicl et al, 2020). Despite the central role of 99m Tc for different diagnostic medical investigations as well as recent industrial implementations, its limited availability at the usage sites is a real difficulty.…”
Section: Main Photon Energy Kevmentioning
confidence: 99%
“…Furthermore, based on its accessible availability and favorable nuclear properties, 99m Tc received considerable attention in multi-disciplinary fields. Recently, it has been involved in a variety of industrial radiotracer applications (Fauquex et al, 1983;Kantzas et al, 2000;Bandeira et al, 2002;Borroto et al, 2003;Berne and Thereska, 2004;Hughes et al, 2004;Thyn and Zitny, 2004;Dash et al, 2012;Pavlovicl et al, 2020). Despite the central role of 99m Tc for different diagnostic medical investigations as well as recent industrial implementations, its limited availability at the usage sites is a real difficulty.…”
Section: Main Photon Energy Kevmentioning
confidence: 99%
“…With its ready availability and favorable nuclear properties, 99m Tc is an attractive radiotracer of choice for applications in the industrial sector and is under study by for several industrial applications (Table 3). 8,[35][36][37][38][39][40][41][42][43][44] The 99 Mo/ 99m Tc generator is useful for several industrial tracer technology applications where:…”
Section: Potentially Useful Irg Systemsmentioning
confidence: 99%
“…In pilot scale industrial systems, the experimentally measured RTD is used to optimize the design parameters and to develop the mathematical model for prediction of the hydrodynamic behavior of the systems. Recent development of radiotracer methodology has also been reported [12]. Recent development of radiotracer methodology has also been reported [12].…”
Section: Introductionmentioning
confidence: 98%