2019
DOI: 10.3221/10.3221/igf-esis.50.29
|View full text |Cite
|
Sign up to set email alerts
|

Simulation of the corrosion-induced damage on aluminum alloy 2024 specimens with equivalent surface notches

Abstract: The effect of corrosion environment aggressiveness on the tensile mechanical properties degradation of AA2024-T3 was investigated. Tensile specimens were pre-corroded for various exposure times to different corrosive solutions, i.e., exfoliation corrosion (EXCO) and 3.5 wt. % NaCl. Then they were tested mechanically. In non-corroded specimens, surface notches of various depths were machined to simulate the degradation of the tensile mechanical properties due to the presence of artificial surface defects. A mec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 30 publications
0
2
0
Order By: Relevance
“…The 2 h exposure to EXCO solution was selected for further investigation because no essential stress decrease is noticed from the tensile flow curves, while a significant ductility decrease is evident (as was found in Alexopoulos, et al 2 ). The same is noticed in Alexopoulos, et al, 55 for the 24 h exposure in the NaCl solution that was selected for further investigation. The specimens were removed and cleaned with acetone before performing the mechanical testing.…”
Section: Prior Exposure Of Specimens To Corrosive Solutionsmentioning
confidence: 71%
See 1 more Smart Citation
“…The 2 h exposure to EXCO solution was selected for further investigation because no essential stress decrease is noticed from the tensile flow curves, while a significant ductility decrease is evident (as was found in Alexopoulos, et al 2 ). The same is noticed in Alexopoulos, et al, 55 for the 24 h exposure in the NaCl solution that was selected for further investigation. The specimens were removed and cleaned with acetone before performing the mechanical testing.…”
Section: Prior Exposure Of Specimens To Corrosive Solutionsmentioning
confidence: 71%
“…Typical tensile curves of the pre-corroded specimens of AA2024-T3 exposed to an EXCO solution and a 3.5 wt% NaCl solution are presented in Figures 3(a) and (b), respectively (as presented in Alexopoulos, et al, 2,55 respectively). The nominal stress calculation was based on the nominal cross section of the tensile specimens, namely, width × thickness = 12.5 mm × 3.2 mm.…”
Section: Effect Of Corrosion Exposure On the Tensile Mechanical Prope...mentioning
confidence: 99%