2020
DOI: 10.1016/j.fusengdes.2020.111516
|View full text |Cite
|
Sign up to set email alerts
|

Simulation of the multi-channel motional Stark effect diagnostic on EAST Tokamak

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…The more tangential beamline (NBI-2L) was selected as the observation target because of better spatial resolution. When viewing from the port C, the radial cross-section between the sightline and the neutral beam is relatively small, the equivalent spatial resolution ranges from 0.9 to 2.3 cm according to the simulation results, which meets the current distribution demand [13]. The MSE periscope installed in the port C is illustrated in figure 1, which consists of a cover glass, a mirror, a sealing glass, a dual-PEM system, a polarizer, and a collecting lens.…”
Section: Optical Layoutmentioning
confidence: 53%
See 1 more Smart Citation
“…The more tangential beamline (NBI-2L) was selected as the observation target because of better spatial resolution. When viewing from the port C, the radial cross-section between the sightline and the neutral beam is relatively small, the equivalent spatial resolution ranges from 0.9 to 2.3 cm according to the simulation results, which meets the current distribution demand [13]. The MSE periscope installed in the port C is illustrated in figure 1, which consists of a cover glass, a mirror, a sealing glass, a dual-PEM system, a polarizer, and a collecting lens.…”
Section: Optical Layoutmentioning
confidence: 53%
“…The interested wavelength range (center wavelength of the σ component) is selected by the narrow bandpass filter. Based on the previous simulations, the full width at half maximum (FWHM) of the filter passing band should be 0.4 nm in order to obtain a high signal-to-noise ratio and strong signal at the same time [13]. The manufacturer of the filter is ALLUXA corporation, and the FWHM of the filter is 0.28±0.1 nm, due to assembly error, the test result is about 0.4 nm.…”
Section: Filter Couplermentioning
confidence: 99%
“…For instance, the optical system is complex and sensitive, requiring precise calibration. Additionally, its reliance on neutral beam injection (NBI) and restrictions on the observation space are factors that cannot be overlooked [34][35][36][37]. Due to the potential sensitivities and uncertainties associated with diagnostic methods, our approach of refining equilibrium calculations, as will be demonstrated in section 4, is applicable regardless of the availability of the diagnostics from MSE or POINT.…”
Section: Current Constraint Of East Equilibrium Reconstructionmentioning
confidence: 99%