2005 International Conference on Electrical Machines and Systems 2005
DOI: 10.1109/icems.2005.202789
|View full text |Cite
|
Sign up to set email alerts
|

Simulation Study of Regenerative Inverter for DC Traction Substation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
10
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(12 citation statements)
references
References 4 publications
0
10
0
Order By: Relevance
“…The transformer-rectifier substations include usually uncontrolled rectifiers, whose pulse number is determined by the traction transformer windings and the static converter configuration [1][2][3][4]. The common schemes are 6-pulse [5,6], 12-pulse [7][8][9][10][11], and even 24-pulse diode-based rectifiers [11][12][13]. The use of controlled rectifiers in the traction substations (TSs) was considered much later.…”
Section: Introductionmentioning
confidence: 99%
“…The transformer-rectifier substations include usually uncontrolled rectifiers, whose pulse number is determined by the traction transformer windings and the static converter configuration [1][2][3][4]. The common schemes are 6-pulse [5,6], 12-pulse [7][8][9][10][11], and even 24-pulse diode-based rectifiers [11][12][13]. The use of controlled rectifiers in the traction substations (TSs) was considered much later.…”
Section: Introductionmentioning
confidence: 99%
“…Transient-state simulations usually rely on the specific simulation software or tools, such as Simulink, Psim, and Pspice. Transient-state simulations are mainly used in equipment-level simulations [41,42] or occasionally in short-circuit simulations [43].…”
Section: Introductionmentioning
confidence: 99%
“…In order to reduce the harmonic distortion of the supply current, a structure of twelve-pulse rectifier is often adopted, consisting of two diode bridges connected in series or in parallel and supplied from two secondary windings of the transformer, one in star connection and the other in delta connection [1], [2]. The common rated DC voltages provided by the rectifier are: 750 V (most trams and metro rail including one in Bucharest); 1500 V (regional express trains and Intercity) and 3 kV (e.g.…”
Section: Introductionmentioning
confidence: 99%
“…The methods identified so far for braking energy recovery involve either the use of various mobile/stationary energy storage devices [8], [9] or the direct return to the AC-power utility [2]- [4], [6], [7], [10], [11].…”
Section: Introductionmentioning
confidence: 99%