2018
DOI: 10.1016/j.solener.2018.02.004
|View full text |Cite
|
Sign up to set email alerts
|

Simulator testing of evacuated flat plate solar collectors for industrial heat and building integration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
14
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 34 publications
(14 citation statements)
references
References 35 publications
0
14
0
Order By: Relevance
“…It results in excellent performance up to 180 • C, but at higher temperatures the low selectivity of the absorber increases the thermal radiation losses, affecting the panel efficiency and limiting the stagnation temperature at about 320 • C with an illumination of 1000 W/m 2 . The increased panel efficiency due to high vacuum has been studied also from other researchers [31] and the superior performance up to 250 • C have been predicted [32], if an optimized SSA was mounted in HVFP. However, the authors did not give any indication on how to produce such optimized SSA.…”
Section: Introductionmentioning
confidence: 86%
“…It results in excellent performance up to 180 • C, but at higher temperatures the low selectivity of the absorber increases the thermal radiation losses, affecting the panel efficiency and limiting the stagnation temperature at about 320 • C with an illumination of 1000 W/m 2 . The increased panel efficiency due to high vacuum has been studied also from other researchers [31] and the superior performance up to 250 • C have been predicted [32], if an optimized SSA was mounted in HVFP. However, the authors did not give any indication on how to produce such optimized SSA.…”
Section: Introductionmentioning
confidence: 86%
“…High vacuum insulation reduces the internal gas convective and conductive losses to a negligible level, keeping high conversion efficiency at high working temperature. The increased panel efficiency due to high vacuum has been studied also from other researchers [33,34]. In HVFP the thermal radiation is the main loss mechanism and the radiative properties of SSA are an aspect of primary importance.…”
Section: Introductionmentioning
confidence: 95%
“…A simulation of such a panel connected to a heating system [82] showed that it would generate an annual heat output by 66% higher than the equivalent area of evacuated tubes and by 112% higher than that obtained from conventional flat plate collectors. Despite the high efficiency of the evacuated flat plate collectors, a problem during their operation was indicated in study [83]. This was related mainly to absorbers, enclosures, and sealing highlights.…”
Section: Introductionmentioning
confidence: 97%
“…The purpose of comparing the two collectors was not only to obtain environmental factors, but also to help in the development of the proposed prototype. Among the collectors, there is an interesting solution currently available commercially, which are evacuated flat plate collectors [82][83][84][85][86]. Works available in the literature relate primarily to improved efficiency, energy optimization, or determining their performance.…”
Section: Introductionmentioning
confidence: 99%