2018
DOI: 10.1016/j.jhazmat.2018.07.080
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of aflatoxin B1, fumonisin B1 and deoxynivalenol in beer samples with a label-free monolithically integrated optoelectronic biosensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
23
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 46 publications
(23 citation statements)
references
References 38 publications
0
23
0
Order By: Relevance
“…Slight agitation is needed followed by centrifugation in order to facilitate the sedimentation of the sample. For the extraction of the contaminated beer sample a method previously developed by Pagkali et al was used [27], since the r-Biopharm protocol was not developed for the analysis of liquid samples. The degassed beer sample was simply diluted 8 times with the r-Biopharm extraction.…”
Section: Sample Preparationmentioning
confidence: 99%
“…Slight agitation is needed followed by centrifugation in order to facilitate the sedimentation of the sample. For the extraction of the contaminated beer sample a method previously developed by Pagkali et al was used [27], since the r-Biopharm protocol was not developed for the analysis of liquid samples. The degassed beer sample was simply diluted 8 times with the r-Biopharm extraction.…”
Section: Sample Preparationmentioning
confidence: 99%
“…In addition to single analyte determinations, multiplexed determinations were also performed through appropriate functionalization of the different MZIs of a single chip with the different biomolecules. Thus, the multiplexed detection of mycotoxins, aflatoxin B 1 , fumonisin B 1 , and deoxynivalenol in beer samples was presented following a competitive immunoassay format with LODs of 0.8, 5.6, and 24 ng/mL for aflatoxin B 1 , fumonisin B 1 , and deoxynivalenol, respectively, and an overall assay duration of 12 min [137]. Through the analysis of beers of different types and origin, the sensor performance was compared with those provided by established instrumental laboratory methods [138].…”
Section: Monolithically Integrated Broad-band Optoelectronic Transducersmentioning
confidence: 99%
“…Moreover, the light coupled to the device was just a little fraction of the incident light [116]. The only reliable solution provided so far to this problem was the implementation as light sources of silicon light emitting diodes (LED) integrated onto the same silicon chip with planar silicon nitride waveguides [117,[119][120][121][122][123][124][125][126][127][128][129][130][131]. The LEDs were silicon avalanche diodes that emitted polychromatic light covering all the visible and near IR spectrum when biased beyond their breakdown point [118].…”
Section: Monolithically Integrated Broad-band Optoelectronic Transducersmentioning
confidence: 99%
“…In addition to single analyte determinations, multiplexed determinations were also performed through appropriate functionalization of the different MZIs of a single chip with the different biomolecules. Thus, the multiplexed detection of mycotoxins, aflatoxin B1, fumonisin B1 and deoxynivalenol in beer samples was presented following a competitive immunoassay format with LODs of 0.8, 5.6 and 24 ng/ml for aflatoxin B1, fumonisin B1 and deoxynivalenol, respectively, and an overall assay duration of 12 min [130]. Through analysis of beers of different types and origin, the sensor performance was compared with those provided by established instrumental laboratory methods [130].…”
Section: Monolithically Integrated Broad-band Optoelectronic Transducersmentioning
confidence: 99%
See 1 more Smart Citation