2007
DOI: 10.1002/rcm.3210
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of aflatoxins, ochratoxin A andFusariumtoxins in maize by liquid chromatography/tandem mass spectrometry after multitoxin immunoaffinity cleanup

Abstract: A liquid chromatography/tandem mass spectrometry method was developed for the simultaneous determination of aflatoxins (B(1), B(2), G(1), G(2)), ochratoxin A, fumonisins (B(1), B(2)), deoxynivalenol, zearalenone, T-2 and HT-2 toxins in maize. A double extraction approach, using a phosphate-buffered solution followed by methanol, was applied to achieve effective co-extraction of the 11 mycotoxins under investigation having quite different polarities and chemical structures. A new multitoxin immunoaffinity colum… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

8
125
1
2

Year Published

2009
2009
2017
2017

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 187 publications
(136 citation statements)
references
References 33 publications
8
125
1
2
Order By: Relevance
“…IAC cleanup should provide a purified sample completely free of the matrix, which allows the use of a solvent calibration curve for quantification. However, as discussed later [41,42], ion suppression/enhancement (caused by the IAC sorbent) has been observed. In the past, IACs were mainly designed for one or two toxins.…”
Section: Immunoaffinity Columnsmentioning
confidence: 93%
See 3 more Smart Citations
“…IAC cleanup should provide a purified sample completely free of the matrix, which allows the use of a solvent calibration curve for quantification. However, as discussed later [41,42], ion suppression/enhancement (caused by the IAC sorbent) has been observed. In the past, IACs were mainly designed for one or two toxins.…”
Section: Immunoaffinity Columnsmentioning
confidence: 93%
“…Huge differences in the extent of matrix effects are not only seen for different matrices; high deviations between individual samples of one matrix type are also observed [58,59]. Matrix effects were present also after highly extensive immunoaffinity cleanup [41,42].…”
Section: Lc-ms/ms-based Approaches Intended For the Targeted Determinmentioning
confidence: 98%
See 2 more Smart Citations
“…The column temperature was maintained at 25°C with the detection wavelength set at 220 nm [27]. The mobile phase ''A'' was water/TFA (1000:1, v/v) and the phase ''B'' was acetonitrile containing TFA (1000:1, v/v).…”
Section: Uplc Analysesmentioning
confidence: 99%