2017
DOI: 10.1590/s2175-97902017000116122
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of atorvastatin and ezetimibe from combined pharmaceutical products by micellar electrokinetic capillary chromatography

Abstract: A rapid and sensitive micellar electrokinetic capillary chromatography method with UV photodiodearray detection was developed for the simultaneous determination of atorvastatin and ezetimibe in fixed dose drug combination. Experimental conditions such as buffer concentration and pH, surfactant concentration, system temperature, applied voltage, injection parameters were optimized in order to improve the efficiency of the separation. The best results were obtained when using fused silica capillary (48 cm length… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
1
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 12 publications
1
1
0
1
Order By: Relevance
“…Furthermore, the higher molecular weight of ATO and its structural bulkiness obviously explain its elution after ROS although they have quite similar pKa values. Similar elution patterns were reported in MEKC separations of ATO-EZE [ 40 ] and EZE-SIM [ 50 ] binary mixtures.…”
Section: Resultssupporting
confidence: 76%
See 1 more Smart Citation
“…Furthermore, the higher molecular weight of ATO and its structural bulkiness obviously explain its elution after ROS although they have quite similar pKa values. Similar elution patterns were reported in MEKC separations of ATO-EZE [ 40 ] and EZE-SIM [ 50 ] binary mixtures.…”
Section: Resultssupporting
confidence: 76%
“…Surveying the literature revealed that different mixtures of EZE with either ATO, ROS or SIM were assayed using various techniques: spectrophotometry [ 15 22 ], spectrofluorimetry [ 23 , 24 ], HPLC [ 19 , 25 35 ], HPTLC [ 34 37 ], UPLC [ 38 ], MEKC [ 39 , 40 ] and CE [ 41 ]. However, there is no reported capillary electrophoresis (CE)-based method for the synchronized determination of the 3 statins together with EZE.…”
Section: Introductionmentioning
confidence: 99%
“…Mérési paraméterek: hőmérséklet 20°C, alkalmazott feszültség +20 kV, injektálási nyomás 50 mbar/1 sec. A detektálás UV fényben 230 nm hullámhossznál történt [17].…”
Section: A Mikroszálak Hatóanyagtartalmának Meghatározásaunclassified