1998
DOI: 10.1016/s0304-4203(98)00037-1
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of dissolved organic carbon and total dissolved nitrogen in seawater by high temperature catalytic oxidation: conditions for precise shipboard measurements

Abstract: Appropriate conditions have been achieve d for the accurate, rapid, and highly precise shipboard simultaneous determination of dissolved organic carbon and total dissolved nitrogen in seawater by high tem perature catalytic oxidation. A nitrogen-specific Antek 705D chemiluminescence detector and a CO 2 -specific LiCor Li6252 IRGA have been coupled inseries with a Shimadzu TOC-5000 organic carbon analy ser. Precision of both sim ultaneous measurements is 1.5%, i.e., ±1 µmol C l -1 and ± 0.3 µmol N l -1 , respe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
59
0

Year Published

2005
2005
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 167 publications
(60 citation statements)
references
References 23 publications
1
59
0
Order By: Relevance
“…The value agreed with the system blank reported in other previous studies (Álvarez-Salgado and Miller, 1998;Badr et al, 2003;Benner and Strom, 1993;Hopkinson et al, 1993;Koike and Tupas, 1993;Suzuki et al, 1992). The blank correction was applied to DOC and TDN data.…”
supporting
confidence: 92%
“…The value agreed with the system blank reported in other previous studies (Álvarez-Salgado and Miller, 1998;Badr et al, 2003;Benner and Strom, 1993;Hopkinson et al, 1993;Koike and Tupas, 1993;Suzuki et al, 1992). The blank correction was applied to DOC and TDN data.…”
supporting
confidence: 92%
“…The catalyser was 0.5% Pt on Al 2 O 3 balls. The DOC concentration of each sample was obtained by subtracting the average (± SD) peak area of 3 to 5 injections (150 µl) from the average (± SD) peak area of the freshly produced Milli-Q water used as a blank and dividing by the slope of the standard curve with potassium hydrogen phthalate (Álvarez-Salgado & Miller 1998).…”
Section: Fluorescence Of Particulate and Dissolved Organic Matter (Dom)mentioning
confidence: 99%
“…The catalyser was 0.5% Pt on Al 2 O 3 balls. The DOC concentration of each sample was obtained by subtracting the average (± SD) peak area of 3 to 5 injections (150 µl) from the average (± SD) peak area of the freshly produced Milli-Q water used as a blank and dividing by the slope of the standard curve with potassium hydrogen phthalate (Álvarez-Salgado & Miller 1998).Aliquots for the quantification of FDOM were collected directly in a quartz cell of 1 cm path-length and measured in a Perkin Elmer LS 55 luminiscence spectrometer. The fluorescence of particulate or ganic matter (FPOM) was obtained by subtracting the FDOM from the fluorescence of the unfiltered sample.…”
mentioning
confidence: 99%
“…were measured with a nitrogen-specific Antek 7020 nitric oxide chemiluminescence detector coupled in series with the carbon-specific Infra-red Gas Analyser of a Shimadzu TOC-5000 organic carbon analyzer, as described in Álvarez-Salgado and Miller (1998) with a precision of ±0.7 µmol C l -1 and ±0.2 µmol N l -1 .…”
Section: Salinity (S)mentioning
confidence: 99%