2010
DOI: 10.1016/j.saa.2010.01.002
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of penicillin G salts by infrared spectroscopy: Evaluation of combining orthogonal signal correction with radial basis function-partial least squares regression

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(4 citation statements)
references
References 26 publications
0
4
0
Order By: Relevance
“…The orthogonal signal correction algorithm (OSC) [ 32 , 33 , 34 ] was used as a method to suppress interference in wound infection detection by e-nose, since it could remove the information that was orthogonal to target signal, where the orthogonal information was recognized as interference information [ 35 ]. The response of the sensor array was analyzed by OSC, and the corrected signals were used as the inputs of RBF.…”
Section: Methods For Suppressing the Interference Caused By Changementioning
confidence: 99%
“…The orthogonal signal correction algorithm (OSC) [ 32 , 33 , 34 ] was used as a method to suppress interference in wound infection detection by e-nose, since it could remove the information that was orthogonal to target signal, where the orthogonal information was recognized as interference information [ 35 ]. The response of the sensor array was analyzed by OSC, and the corrected signals were used as the inputs of RBF.…”
Section: Methods For Suppressing the Interference Caused By Changementioning
confidence: 99%
“…As mentioned, 373 papers were published in the period of 2005–2012. Some of these papers that include different area of applications and/or different journals are cited in this paper . These articles cover applications of PLS, PCR, orthogonal signal correction‐PLS, genetic algorithm‐PLS (GA‐PLS), multiple linear regression, and a few MVC‐ANN for simultaneous analysis using first‐order data.…”
Section: Review Of Some Published Materials By Iranian Chemists In DImentioning
confidence: 99%
“…Over the last 10 years, orthogonal methods have been developed and used in spectroscopic data analysis for calibration , classification , and calibration transfer . They have also been extensively used in “omics” applications, for example, to analyze data from nuclear magnetic resonance (NMR) or gas chromatography/mass spectroscopy (GC‐MS)‐based technologies (proteomics and metabolomics) .…”
Section: Introductionmentioning
confidence: 99%