The radionuclide pair (214)Bi and (214)Po which belongs to the uranium series interferes with airborne radionuclide measurement needed for the radiation management of a nuclear facility. Time intervals between (214)Bi (β) and (214)Po (α) are much shorter than artificial radionuclides due to the short half-life of (214)Po (164 μs). The purpose of this study is to develop of a new analytical method (time interval analysis: TIA) based on the beta-alpha coincidence method for selective measurement of (214)Bi-(214)Po. The developed method was applied to an actual dust-filter measurement. The TIA system was highly effective in measuring of the filter with background subtraction.