2017
DOI: 10.1016/j.vibspec.2017.03.001
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of rifampicin, isoniazid, pyrazinamide and ethambutol in 4-FDC tablet by Raman spectroscopy associated to chemometric approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(9 citation statements)
references
References 30 publications
0
8
0
1
Order By: Relevance
“…The pre-processing method of Automatic Whitacre Fitting Algorithm (AWF) was used to remove the fluorescence background of Raman spectra after acquisition. Correlation coefficient ( R c ), root mean square error of correction ( RMSE c ), prediction coefficient ( R p ) and root mean square error of prediction ( RMSE p ) were used to evaluate the performance of the models ( Chellini et al., 2017 ). Higher R p , R c values and lower RMSE c , RMSE p values demonstrate better model performance ( Guo et al., 2021 ).…”
Section: Methodsmentioning
confidence: 99%
“…The pre-processing method of Automatic Whitacre Fitting Algorithm (AWF) was used to remove the fluorescence background of Raman spectra after acquisition. Correlation coefficient ( R c ), root mean square error of correction ( RMSE c ), prediction coefficient ( R p ) and root mean square error of prediction ( RMSE p ) were used to evaluate the performance of the models ( Chellini et al., 2017 ). Higher R p , R c values and lower RMSE c , RMSE p values demonstrate better model performance ( Guo et al., 2021 ).…”
Section: Methodsmentioning
confidence: 99%
“…5 Thus, it is significant to assess the level of RIF simply and accurately in drugs, food and human blood samples. Multiple analytical methods have been used to analyze RIF, such as UV–visible spectrophotometry, 6 chemiluminescence, 7 Raman spectroscopy, 8 high-performance liquid chromatography (HPLC) 9 and mass spectroscopy (MS). 10 Nevertheless, these methods often require difficult sample preparation, have complex pretreatment steps, are time consuming and bear high costs.…”
Section: Introductionmentioning
confidence: 99%
“…A variety of analytical approaches such as high-performance liquid chromatography, Raman spectroscopy, chemiluminescence, colorimetry, capillary electrophoresis, uorimetry, chemometry, titrimetry, polarography, and spectrophotometry are used for INZ analysis. [5][6][7][8][9] All these techniques have their own advantages but every technique has some limitations. Therefore, efforts are underway to search for effective tools on case to case basis.…”
Section: Introductionmentioning
confidence: 99%