2000
DOI: 10.1016/s0039-128x(99)00082-3
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of urinary androgen glucuronides by high temperature gas chromatography-mass spectrometry with selected ion monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
17
0

Year Published

2003
2003
2014
2014

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 51 publications
(20 citation statements)
references
References 13 publications
3
17
0
Order By: Relevance
“…II). High-temperature GC techniques ( 36,38,39 ), which can separate high molecular weight or lipophilic compounds that cannot be eluted using conventional fused-silica capillary GC columns, were examined. By using a thermally stable, stainless steel MXT-1 capillary col- (from 10 s to 30 min) combined with various mixing techniques (sonication, mechanical shaking, and vortexing) and reaction temperatures (25 and 50°C).…”
Section: Gc-ms Characteristics Of the Derivativesmentioning
confidence: 99%
“…II). High-temperature GC techniques ( 36,38,39 ), which can separate high molecular weight or lipophilic compounds that cannot be eluted using conventional fused-silica capillary GC columns, were examined. By using a thermally stable, stainless steel MXT-1 capillary col- (from 10 s to 30 min) combined with various mixing techniques (sonication, mechanical shaking, and vortexing) and reaction temperatures (25 and 50°C).…”
Section: Gc-ms Characteristics Of the Derivativesmentioning
confidence: 99%
“…The heated capillary temperature was maintained at 250°C. To prepare a calibration curve, we removed T-G and DHT-G from pooled urine by solid-phase extraction (9 ). Urine samples with increasing concentrations of added analyte (0.2-400 g/L T-G and 3-200 g/L DHT-G) and a fixed concentration of added d 3 -T-G (20 L; 1 mg/L) as an IS were then analyzed according to the procedure described above.…”
mentioning
confidence: 99%
“…Afterwards, the coupling rate was calculated according to the Lambert-Beer law and the formulas referred to in Choi et al (2000).…”
Section: Coupling Rate Of Mpa-bsa Formationmentioning
confidence: 99%
“…The relative molecular mass of MPA is only 344.5 and it has no immunogenicity, so it cannot stimulate animals to produce a corresponding antibody directly, though it has immune reactivity and can form a hapten-antibody complex with its specific antibody. Moreover, without coupling with a carrier protein, low-molecular substances are poorly absorbed by solid-phase carriers; through the protein, the hapten can be invested to the solid-phase carrier (Choi et al, 2000).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation