Simultaneous Electrochemical Detection of Cd2+ and Pb2+ Based on an MOF-Derived Carbon Composite Linked with Multiwalled Carbon Nanotubes

Abstract: Heavy metal ion (HMI) pollution is a serious threat to human health and the ecosystem. Therefore, there is an urgent need to develop a fast and sensitive platform for heavy metal ion detection. In this work, a novel sensing platform based on ZIF-67-derived cobalt/nitrogen-doped carbon (NC) composite polyhedrons linked with multiwalled carbon nanotubes (MWCNTs), termed Co@NC/MWCNT, for the simultaneous monitoring of Cd2+ and Pb2+ was established. In detail, nanoporous ZIF-67 was first in situ grown on the MWCNT… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
12
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(13 citation statements)
references
References 57 publications
1
12
0
Order By: Relevance
“…In addition, at 787.3 and 803.0 eV are the satellite peaks of both of them. The same result was obtained as other reports, 42,43 proving that C-ZIF-67/SP was successfully prepared.…”
Section: Structure and Morphology Characterization Of The Materialssupporting
confidence: 90%
“…In addition, at 787.3 and 803.0 eV are the satellite peaks of both of them. The same result was obtained as other reports, 42,43 proving that C-ZIF-67/SP was successfully prepared.…”
Section: Structure and Morphology Characterization Of The Materialssupporting
confidence: 90%
“…Consistently, the response signals increase rapidly while the deposition time increased from 30 to 180 s (Figure S10b). However, the stripping currents reach a plateau when the deposition time is further increased, probably due to the saturation of HMI adsorption sites . Thus, a deposition time of 180 s is selected in the following experiments.…”
Section: Resultsmentioning
confidence: 99%
“…However, the stripping currents reach a plateau when the deposition time is further increased, probably due to the saturation of HMI adsorption sites. 55 Thus, a deposition time of 180 s is selected in the following experiments. The effect of solution pH on E(6)-C-HP-ZIF-8 sensing performance is presented in Figure S10c in the SI.…”
Section: Optimization Of Sensing Conditionsmentioning
confidence: 99%
“…However, it has also brought about a range of environmental issues causing a significant threat to human health. [1][2][3][4][5] Among these issues, there is an increasing concern about water pollution, largely attributed to the existence of heavy metal ions (HMIs). [6][7][8][9][10][11] HMIs like Cd 2+ , Hg 2+ , Cr 2+ , and Pb 2+ are hard pollutants that resist biodegradation and tend to accumulate in organisms through ecological chains.…”
Section: Introductionmentioning
confidence: 99%
“…The rapid expansion of industrial demand has contributed to economic progress. However, it has also brought about a range of environmental issues causing a significant threat to human health 1–5 . Among these issues, there is an increasing concern about water pollution, largely attributed to the existence of heavy metal ions (HMIs) 6–11 .…”
Section: Introductionmentioning
confidence: 99%