2020
DOI: 10.1016/j.chroma.2019.460752
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous enantioseparation of nonsteroidal anti-inflammatory drugs by a one-dimensional liquid chromatography technique using a dynamically coated chiral porous silicon pillar array column

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 39 publications
0
7
0
Order By: Relevance
“…Enantioseparation of several non-steroidal anti-inflammatory drugs (ketoprofen, ketorolac, indoprofen, fenoprofen, suprofen, ibuprofen, and flurbiprofen) was performed using a dynamically coated pillar array column with hydroxypropyl-β-CD as a CS with improved enantioresolution [ 15 ]. Several works published the use of β-CD derivatives in counter current chromatography.…”
Section: Cyclodextrin-based Stationary Phasesmentioning
confidence: 99%
“…Enantioseparation of several non-steroidal anti-inflammatory drugs (ketoprofen, ketorolac, indoprofen, fenoprofen, suprofen, ibuprofen, and flurbiprofen) was performed using a dynamically coated pillar array column with hydroxypropyl-β-CD as a CS with improved enantioresolution [ 15 ]. Several works published the use of β-CD derivatives in counter current chromatography.…”
Section: Cyclodextrin-based Stationary Phasesmentioning
confidence: 99%
“…The concentration of the CSP in the solution determines the thickness of the stationary phase film [ 41 ]. Dynamic coating allows the replacement of the selector being one of the benefits for this technique [ 42 ].…”
Section: Coating Methodsmentioning
confidence: 99%
“…Another example of a dynamic coating procedure was described by Naghdi et al [ 42 ], specifically, of coating hydroxypropyl-β-cyclodextrin onto porous silica. The new CSP was prepared in a pillar array column, a feasible alternative to packed bed columns and monoliths since they allowed a homogeneous flow direction and a reduced back pressure.…”
Section: Coating Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A chiral liquid chromatography column, prepared by coating hydroxypropyl-β-cyclodextrin onto a reversed-phase porous silicon pillar array column, was developed by Naghdi et al [ 81 ]. The ES efficiency of the developed column was evaluated with mixtures of non-steroidal anti-inflammatory drugs as the analytes, under nano-LC conditions.…”
Section: β-Cyclodextrin-based Cspsmentioning
confidence: 99%