1985
DOI: 10.1016/0003-2697(85)90405-1
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous extraction and reverse-phase high-performance liquid chromatographic determination of adenine and pyridine nucleotides in human red blood cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
158
1
2

Year Published

1993
1993
2011
2011

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 339 publications
(164 citation statements)
references
References 20 publications
3
158
1
2
Order By: Relevance
“…After neutralization with 3 M KOH/1.5 M Tris, samples were centrifuged at 20,800 g for 5 min at 4°C. The resulting supernatants were assayed for ATP determination by separation in a reverse-phase high-performance liquid chromatography (HPLC), with detection at 254 nm, as described previously (Stocchi et al, 1985). ADP and AMP levels were undetectable in our samples.…”
Section: Measurement Of Atp and Phosphocreatinementioning
confidence: 99%
“…After neutralization with 3 M KOH/1.5 M Tris, samples were centrifuged at 20,800 g for 5 min at 4°C. The resulting supernatants were assayed for ATP determination by separation in a reverse-phase high-performance liquid chromatography (HPLC), with detection at 254 nm, as described previously (Stocchi et al, 1985). ADP and AMP levels were undetectable in our samples.…”
Section: Measurement Of Atp and Phosphocreatinementioning
confidence: 99%
“…The supernatants were neutralized with 10 M KOH in 5 M Tris and further centrifuged at 15,800 Â g, for 10 min at 4 8C to remove the potassium perchlorate salt. The resulting supernatants were assayed for adenosine triphosphate (ATP) using a reverse-phase HPLC methodology, as described by Stocchi et al (1985) The chromatographic apparatus was a Beckman System Gold, consisting of a 126 binary Pump Model and a 166 Variable UV detector controlled by a computer. The column was a Lichrospher 100 RP-18 (5 mM) from Merck (Germany).…”
Section: Determination Of Atp Levelsmentioning
confidence: 99%
“…The pellets were used to determine the protein content by the Sedmak method [20], whereas the supernatants were neutralized with 10 M KOH/5 M Tris and centrifuged at 15,800 ϫ g for 10 min. The resulting supernatants were analyzed by separation in a reverse-phase HPLC, as described by Stocchi et al [21]. The chromatographic apparatus used was a Beckman-System Gold, consisting of a 126 Binary Pump Model, a 166 Variable UV detector and a Lichrospher 100 RP-18 (5 m) column, from Merck (Darmstadt, Germany).…”
Section: Determination Of Cellular Energy Chargementioning
confidence: 99%