2012
DOI: 10.1016/j.jpba.2012.08.004
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous measurement of adenosine, dopamine, acetylcholine and 5-hydroxytryptamine in cerebral mice microdialysis samples by LC–ESI-MS/MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
22
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 41 publications
(25 citation statements)
references
References 10 publications
3
22
0
Order By: Relevance
“…We would like to state that while AcbC is a good target for sampling DA it might not be a good option for NE, EP, 5-HT or AD sampling. However, these neurochemicals have been collected and measured from AcbC as previously reported (Salem and Hope, 1999;Del Arco et al, 2008;Hernandez et al, 2008;Rada et al, 2010;Cannazza et al, 2012;Dobbs and Mark, 2012;Munari et al, 2013;Pajski and Venton, 2013;Dautan et al, 2014). Thus, these evidences indicate the trustworthy of our study.…”
Section: Discussionsupporting
confidence: 77%
“…We would like to state that while AcbC is a good target for sampling DA it might not be a good option for NE, EP, 5-HT or AD sampling. However, these neurochemicals have been collected and measured from AcbC as previously reported (Salem and Hope, 1999;Del Arco et al, 2008;Hernandez et al, 2008;Rada et al, 2010;Cannazza et al, 2012;Dobbs and Mark, 2012;Munari et al, 2013;Pajski and Venton, 2013;Dautan et al, 2014). Thus, these evidences indicate the trustworthy of our study.…”
Section: Discussionsupporting
confidence: 77%
“…Moriarty et al provide a LC-ESI-MS/MS method for the analysis of SRT and related compounds in urine and achieved LODs of 8.8–18.2 nM and LOQs of 29.4 – 55.7 nM [42]. Only a few publications measuring neurotransmitters in brain microdialysates exist, including Suominen et al presenting LODs for DA and SRT analyzed by LC-ESI-MS/MS of 0.20 nM (3 fmol injected onto the column) and an LOQ of 0.5 nM for DA and 1 nM for SRT [16, 17, 43]. Due to the high sensitivity of the developed method (LOQ DA: 0.37 nM; LOQ SRT: 0.14 nM; summarized in Table 2), the number of requisite worms (L1 stage) could be reduced to about 2,000 per sample compared to other HPLC methods requiring hundreds of thousands worms (200,000 worms) per sample [34, 44, 45].…”
Section: Discussionmentioning
confidence: 99%
“…, and tph2 −/− embryos at E10.5 were obtained and used for the analysis as previously described (Carrera et al, 2007;Cannazza et al, 2012). The standard substance of 5-HT was purchased from Sigma-Aldrich.…”
Section: Lc-ms Analysismentioning
confidence: 99%