2021
DOI: 10.1039/d0an02335c
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous measurement of free and conjugated estrogens in surface water using capillary liquid chromatography tandem mass spectrometry

Abstract: Given detrimental impacts induced by estrogens at trace level, determination of them is significant but challenging due to their low content in environmental samples and inherent weak ionisation. A modified...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
3
1

Year Published

2022
2022
2025
2025

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(6 citation statements)
references
References 79 publications
2
3
1
Order By: Relevance
“…2, it is evident that recoveries obtained using cartridges packed with CC/HNO 3 were comparable to the recoveries gained by commercial cartridges. The performance of the proposed method was also comparable with some previously reported methods (Coelho et al 2020;Li et al 2021;Huang et al 2021), where expensive commercial cartridges were used, indicating the cost-effectiveness of this method.…”
Section: Methods Validationsupporting
confidence: 74%
“…2, it is evident that recoveries obtained using cartridges packed with CC/HNO 3 were comparable to the recoveries gained by commercial cartridges. The performance of the proposed method was also comparable with some previously reported methods (Coelho et al 2020;Li et al 2021;Huang et al 2021), where expensive commercial cartridges were used, indicating the cost-effectiveness of this method.…”
Section: Methods Validationsupporting
confidence: 74%
“…As seen before, DMIS interacted exclusively with the hydroxyl group on the phenolic ring and it was not reactive with the 17-hydroxyl group of estrogens (represented in Fig. 3 ; Keski-Rahkonen et al, 2015 ; Huang et al, 2021 ). Further, catechol estrogens showed double derivatives, but not mono derivatives as DMIS bound to both hydroxyl groups of the A-ring ( Table 1 ).…”
Section: Resultssupporting
confidence: 59%
“…Sulphate steroid conjugates have low logP and high aqueous solubility values (logS), as seen in Table S1, indicating hydrophilic characteristics leading to their occurrence in water samples. Nevertheless, low concentrations, <10.4 pg•L −1 [55], <LOD [56], and up to 1.46 ng•L −1 in Spain [45], have been reported in surface waters upon dilution once entering the…”
Section: Steroid Hormonesmentioning
confidence: 99%