Intracranial Pressure and Brain Biochemical Monitoring 2002
DOI: 10.1007/978-3-7091-6738-0_51
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Measurement of Local Cortical Blood Flow and Tissue Oxygen Saturation by Near Infra-Red Laser Doppler Flowmetry and Remission Spectroscopy in the Pig Brain

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
31
0

Year Published

2005
2005
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(32 citation statements)
references
References 8 publications
1
31
0
Order By: Relevance
“…The measurement device, O 2 C (Oxygen to See; LEA Medizintechnik, GieQen, Germany), was already validated by Walter et al in an experimental works on 9 anesthetized young pigs. 3 It represented a very good correlation coefficient (r = 0.92). Furthermore, the laser Doppler flowmetry and the microlightguide spectrophotometry are widely used in numerous microvascular studies to evaluate its effectiveness on monitoring flap perfusion and viability.…”
Section: Discussionmentioning
confidence: 91%
“…The measurement device, O 2 C (Oxygen to See; LEA Medizintechnik, GieQen, Germany), was already validated by Walter et al in an experimental works on 9 anesthetized young pigs. 3 It represented a very good correlation coefficient (r = 0.92). Furthermore, the laser Doppler flowmetry and the microlightguide spectrophotometry are widely used in numerous microvascular studies to evaluate its effectiveness on monitoring flap perfusion and viability.…”
Section: Discussionmentioning
confidence: 91%
“…The method of the O2C device, light guide tissue spectrophotometry, which combines laser Doppler fluxmetry and tissue spectrometry used for measuring relative blood flow, hemoglobin amount, and hemoglobin oxygenation, has been described in detail elsewhere [15][16][17].…”
Section: Discussionmentioning
confidence: 99%
“…The O2C calculates from the absorbed part of the relative hemoglobin amount for the illuminated tissue volume. This measurement represents the hemoglobin amount per tissue volume and is independent of the vessel density, vessel lumen level, and hemoglobin quantity in the blood [13,14].…”
Section: The O2c Measurement Principlementioning
confidence: 99%
“…Reference values in the healthy controls are between 10 and 50 AU on the arm or leg. Values below 5 are thought to be problematic [14].…”
Section: The O2c Measurement Principlementioning
confidence: 99%