Simultaneous Measurement of Local Cortical Blood Flow and Tissue Oxygen Saturation by Near Infra-Red Laser Doppler Flowmetry and Remission Spectroscopy in the Pig Brain
“…The measurement device, O 2 C (Oxygen to See; LEA Medizintechnik, GieQen, Germany), was already validated by Walter et al in an experimental works on 9 anesthetized young pigs. 3 It represented a very good correlation coefficient (r = 0.92). Furthermore, the laser Doppler flowmetry and the microlightguide spectrophotometry are widely used in numerous microvascular studies to evaluate its effectiveness on monitoring flap perfusion and viability.…”
The postoperative perfusion characteristics of the DIEP flap showed a critical drop in the cutaneous oxygen supply and blood flow on the third postoperative day. This represents a potential risk and should be considered in the postoperative management of the DIEP flap.
“…The measurement device, O 2 C (Oxygen to See; LEA Medizintechnik, GieQen, Germany), was already validated by Walter et al in an experimental works on 9 anesthetized young pigs. 3 It represented a very good correlation coefficient (r = 0.92). Furthermore, the laser Doppler flowmetry and the microlightguide spectrophotometry are widely used in numerous microvascular studies to evaluate its effectiveness on monitoring flap perfusion and viability.…”
The postoperative perfusion characteristics of the DIEP flap showed a critical drop in the cutaneous oxygen supply and blood flow on the third postoperative day. This represents a potential risk and should be considered in the postoperative management of the DIEP flap.
“…The method of the O2C device, light guide tissue spectrophotometry, which combines laser Doppler fluxmetry and tissue spectrometry used for measuring relative blood flow, hemoglobin amount, and hemoglobin oxygenation, has been described in detail elsewhere [15][16][17].…”
Laparoscopic inguinal hernia repair for babies weighing 5 kg or less is feasible, safe, and perhaps even less technically demanding than open herniotomy.
“…The O2C calculates from the absorbed part of the relative hemoglobin amount for the illuminated tissue volume. This measurement represents the hemoglobin amount per tissue volume and is independent of the vessel density, vessel lumen level, and hemoglobin quantity in the blood [13,14].…”
Section: The O2c Measurement Principlementioning
confidence: 99%
“…Reference values in the healthy controls are between 10 and 50 AU on the arm or leg. Values below 5 are thought to be problematic [14].…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.