2017
DOI: 10.1016/j.mri.2016.12.001
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous measurement of total water content and myelin water fraction in brain at 3 T using a T 2 relaxation based method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
26
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 39 publications
(30 citation statements)
references
References 50 publications
4
26
0
Order By: Relevance
“…47 Our relatively high SNR and additional echoes at short T 2 times (compared to the more common ΔTE of 10 ms) should allow signal amplitude fluctuations at early echoes, because of stimulated echo artifacts, to be more easily distinguished from signal reduction due to short T A B L E 4 Mean and SD of the MWF ROI values and corresponding repeatability metrics for multi-echo T 2 relaxation imaging with compressed sensing and partial Fourier acceleration (METRICS-PF) repeatability subjects' scan 1 and scan 2 For METRICS and METRICS-PF, our mean MWF LOA (−2.2|2.9 and −1.4|2.0) and RC (1.5 and 1.1) are comparable to those of the 2D GRASE sequence with parallel imaging acceleration factors (AF) of 1 (LOA = −2.4|2.3, RC = 1.9) and 2 (LOA = −2.5|2.9, RC = 2.1). 22 Our mean MWF COV of 6.2% and 4.5% are comparable or better than that reported for single-slice 2D MSE (19%, 12.6%), 48,49 3D MSE (intra-site 3.99%, inter-site 4.68%), 18 3D GRASE (single subject 13.4%), 50 and 2D MS GRASE (6.1% for AF = 1, 6.7% for AF = 2). 22 Our mean MWF ICC (0.79 and 0.84) are comparable to that of 3D MSE (intra-site 0.76, inter-site 0.69), 18 3D GRASE (0.83), 51 and 2D MS GRASE (0.88 for AF = 1, 0.80 for AF = 2).…”
Section: Quality and Repeatabilitysupporting
confidence: 69%
“…47 Our relatively high SNR and additional echoes at short T 2 times (compared to the more common ΔTE of 10 ms) should allow signal amplitude fluctuations at early echoes, because of stimulated echo artifacts, to be more easily distinguished from signal reduction due to short T A B L E 4 Mean and SD of the MWF ROI values and corresponding repeatability metrics for multi-echo T 2 relaxation imaging with compressed sensing and partial Fourier acceleration (METRICS-PF) repeatability subjects' scan 1 and scan 2 For METRICS and METRICS-PF, our mean MWF LOA (−2.2|2.9 and −1.4|2.0) and RC (1.5 and 1.1) are comparable to those of the 2D GRASE sequence with parallel imaging acceleration factors (AF) of 1 (LOA = −2.4|2.3, RC = 1.9) and 2 (LOA = −2.5|2.9, RC = 2.1). 22 Our mean MWF COV of 6.2% and 4.5% are comparable or better than that reported for single-slice 2D MSE (19%, 12.6%), 48,49 3D MSE (intra-site 3.99%, inter-site 4.68%), 18 3D GRASE (single subject 13.4%), 50 and 2D MS GRASE (6.1% for AF = 1, 6.7% for AF = 2). 22 Our mean MWF ICC (0.79 and 0.84) are comparable to that of 3D MSE (intra-site 0.76, inter-site 0.69), 18 3D GRASE (0.83), 51 and 2D MS GRASE (0.88 for AF = 1, 0.80 for AF = 2).…”
Section: Quality and Repeatabilitysupporting
confidence: 69%
“…These concentrations are in good agreement with previous studies using myelin water imaging. [49][50][51] The values are also in good agreement with a conversion between MWF and MVF presented recently. 52 Note, however, that myelin not only affects the R 2 * of myelin water but all water in the vicinity of myelin.…”
Section: Discussionsupporting
confidence: 90%
“…Assuming a myelin water content of 50%, the MVF of 17.32% in controls, 18.19% in siblings, and 16.02% in patients translate to MWFs of 8.66%, 9.10%, and 8.01%, respectively. These concentrations are in good agreement with previous studies using myelin water imaging . The values are also in good agreement with a conversion between MWF and MVF presented recently .…”
Section: Discussionmentioning
confidence: 99%
“…To the best of our knowledge, PD-weighted MRI has never been used to assess hydration states within the vocal folds of rats, although it has been used to assess water content in other tissue. [14][15][16][17][18] Systemic dehydration was defined as 10% loss in body weight resulting from withholding water. A loss of 1% body weight due to diuretic ingestion in young, healthy adults can negatively affect voice.…”
Section: Introductionmentioning
confidence: 99%